Smeg GW0160 Скачать руководство пользователя страница 6

 

 

 

 

0160, 1160, 4060, 4190 

Power Connection Conversion instruction 

Page 6 - 9 

 

ILLUSTRATION 

PROCEDURE 

 

5.

 

 On WD4190 and GW4190 you must remove the top of 
the device, to access: 

.to fuses 

.to the mains switch (SZ) 

placed in the right-hand side cabinet. 

The top is fixed to the machine at the rear by means of 
two screws, crosshead. 

6.

 

key to main components: 

 

. fuse terminal clamps 
 

 

. power supply terminal board 
 

 

. voltage change terminal board “XCT” (configuration 
shown is 400 V 3N~) 
 

 

 

7.

 

The first component to be replaced (or adapted by 
cutting the unused wires) is the power cable. 

 
(PAY ATTENTION: on WD4190 and GW4190 the power 
cord is placed in the side cabinet). 
 

If replacement is necessary, proceed as follows: 

 

. Unscrew the fixing screws which secure the terminals at the 
end of the cable and release the terminals;  
. Connect the new power cable to the old one (still in place) 
using adhesive tape;  
 

Содержание GW0160

Страница 1: ...e units with neutral 400V 3N 7 0kW can be converted on site to the corresponding 230V single phase version 230V 2 8kW The technical data plates of these devices state the two possible electrical conne...

Страница 2: ...rable 400V 3N 50Hz 12A 7000W 230V 50Hz 12A 2800W FUSES 10 3x38 16 A ON POWER SUPPLY L1 L2 L3 In the table the characteristics of the power supply cable supplied with the configurable appliances produc...

Страница 3: ...IRING DIAGRAM Refer to the latest electrical wiring diagram at www smegtech com The section of the diagram involved in this procedure is shown below 2 1 POWER SUPPLY 0160 1160 4060 Default configurati...

Страница 4: ...0160 1160 4060 4190 Power Connection Conversion instruction Page 4 9 2 2 POWER SUPPLY 4190 Default configuration Configurable connection single phase 400V 3N 50Hz 12A 7000W 230V 50Hz 12A 2800W...

Страница 5: ...sides which secure the bottom door 2 Disconnect the earth wire fixed to the left hand corner of the part and pull the door outward 3 Remove the drip guard Undo the fixing screws at the sides Lift up...

Страница 6: ...mponents fuse terminal clamps power supply terminal board voltage change terminal board XCT configuration shown is 400 V 3N 7 The first component to be replaced or adapted by cutting the unused wires...

Страница 7: ...the mains switch SZ Apply the same prescriptions as above Rear view 9 On WD4190 and GW4190 it is necessary to act on the mains switch TERMINALS Mains Switch maintaining in the case of single phase onl...

Страница 8: ...n data plate 230V 1N single phase 230V wiring side L1 and L3 connected to the same terminal clamp L1 L2 and N connect to the same terminal clamp 12 Move the jumpers on the voltage change terminal boar...

Страница 9: ...e Use the technical application to check that the device s inputs and outputs function correctly Set the type of connection 3 three phase 1 single phase in the SET UP menu following the procedure prov...

Отзывы: