Power Connection Conversion instruction 

Page 7 - 9 

 

ILLUSTRATION 

PROCEDURE 

 

. Loosen the cable gland on the rear cross-bar and pull the 
whole of the old cable out of the back of the appliance; 
. Leave about 30 cm of the new cable (including the stripped 
part) on the front cross-bar to allow the contacts to be restored; 
. Connect the terminals of the new power cable to the fuse 
terminal clamps and connect the earth wire to the power supply 
terminal board (check that if the cable is pulled, the earth wire 
is always the last one to become taut).

 

Front view MAINS SWITCH “SZ”

 

 

8.

 

On WD4190 and GW4190 only, the power cord is 
housed in the side cabinet and ends within the 
terminals of the mains switch "SZ". 

Apply the same prescriptions as above. 

Rear view 

 

9.

 

On WD4190 and GW4190: it is necessary to act on the 
mains switch TERMINALS ("Mains Switch"): 
maintaining, in the case of single-phase, only the 
phase L1 and the neutral N.
 

The adjacent images: front and rear view of the mains 
switch. On 0160, 1160, 4060 models, the electric switch is 
not installed. 

10.

 

Use the fuse holder - power supply terminal board connection wires to create the configuration required, 

checking it using the electrical wiring diagram and a tester. 

 

. 400V 3N~ - three-phase 400V with neutral 
. FUSES 16 A 
 
In this configuration, the neutral is connected directly to 
the terminal board and not to the fuse holder. 

 

. 230V 1N~ - single-phase 230V 
. FUSES 16 A 
 
In this configuration, the neutral is connected to the fuse 
holder. 

11.

 

Modify the power supply terminal board to create the electrical configuration required, as shown in the 

Содержание GW0160

Страница 1: ...e units with neutral 400V 3N 7 0kW can be converted on site to the corresponding 230V single phase version 230V 2 8kW The technical data plates of these devices state the two possible electrical conne...

Страница 2: ...rable 400V 3N 50Hz 12A 7000W 230V 50Hz 12A 2800W FUSES 10 3x38 16 A ON POWER SUPPLY L1 L2 L3 In the table the characteristics of the power supply cable supplied with the configurable appliances produc...

Страница 3: ...IRING DIAGRAM Refer to the latest electrical wiring diagram at www smegtech com The section of the diagram involved in this procedure is shown below 2 1 POWER SUPPLY 0160 1160 4060 Default configurati...

Страница 4: ...0160 1160 4060 4190 Power Connection Conversion instruction Page 4 9 2 2 POWER SUPPLY 4190 Default configuration Configurable connection single phase 400V 3N 50Hz 12A 7000W 230V 50Hz 12A 2800W...

Страница 5: ...sides which secure the bottom door 2 Disconnect the earth wire fixed to the left hand corner of the part and pull the door outward 3 Remove the drip guard Undo the fixing screws at the sides Lift up...

Страница 6: ...mponents fuse terminal clamps power supply terminal board voltage change terminal board XCT configuration shown is 400 V 3N 7 The first component to be replaced or adapted by cutting the unused wires...

Страница 7: ...the mains switch SZ Apply the same prescriptions as above Rear view 9 On WD4190 and GW4190 it is necessary to act on the mains switch TERMINALS Mains Switch maintaining in the case of single phase onl...

Страница 8: ...n data plate 230V 1N single phase 230V wiring side L1 and L3 connected to the same terminal clamp L1 L2 and N connect to the same terminal clamp 12 Move the jumpers on the voltage change terminal boar...

Страница 9: ...e Use the technical application to check that the device s inputs and outputs function correctly Set the type of connection 3 three phase 1 single phase in the SET UP menu following the procedure prov...

Отзывы: