POWER CONFIGURATION 

 
 

MODELS

 

VARIANTS 

POWER 

CONNECTION 

DESCRIPTION 

ELECTRICITY SUPPLY 

PROTECTIVE DEVICES 

INCORPORATED IN THE APPLIANCE 

WD1160 
WD4060 
WD4190 
GW0160 
GW1160 
GW4060 
GW4190

 

Standard  

(400V three-

phase variants 

with neutral) 

400V three-phase 

configurable 

400V 3N~ / 50Hz / 12A / 7000W 

*

 

230V ~ / 50Hz / 12A / 2800W 

FUSES 10.3x38 16 A ON POWER 

SUPPLY  

[L1, L2, L3] 

 
 
In the table: the characteristics of the power supply cable supplied with the configurable appliances, product technical 
data plate and data plate which confirms the electrical configuration actually set up during installation. 
 

POWER SUPPLY CABLE TECHNICAL DATA 

 

FROR 5 x 2.5 mm

(5G2,5), 450/750 V, IMQ mark 

 
FACSIMILE OF CONFIGURABLE PRODUCT TECHNICAL DATA PLATE 

 

DATA PLATE FOR USE BY AUTHORISED ELECTRICIAN TO CONFIRM ACTUAL CONFIGURATION 

 

 
 

Содержание GW0160

Страница 1: ...e units with neutral 400V 3N 7 0kW can be converted on site to the corresponding 230V single phase version 230V 2 8kW The technical data plates of these devices state the two possible electrical conne...

Страница 2: ...rable 400V 3N 50Hz 12A 7000W 230V 50Hz 12A 2800W FUSES 10 3x38 16 A ON POWER SUPPLY L1 L2 L3 In the table the characteristics of the power supply cable supplied with the configurable appliances produc...

Страница 3: ...IRING DIAGRAM Refer to the latest electrical wiring diagram at www smegtech com The section of the diagram involved in this procedure is shown below 2 1 POWER SUPPLY 0160 1160 4060 Default configurati...

Страница 4: ...0160 1160 4060 4190 Power Connection Conversion instruction Page 4 9 2 2 POWER SUPPLY 4190 Default configuration Configurable connection single phase 400V 3N 50Hz 12A 7000W 230V 50Hz 12A 2800W...

Страница 5: ...sides which secure the bottom door 2 Disconnect the earth wire fixed to the left hand corner of the part and pull the door outward 3 Remove the drip guard Undo the fixing screws at the sides Lift up...

Страница 6: ...mponents fuse terminal clamps power supply terminal board voltage change terminal board XCT configuration shown is 400 V 3N 7 The first component to be replaced or adapted by cutting the unused wires...

Страница 7: ...the mains switch SZ Apply the same prescriptions as above Rear view 9 On WD4190 and GW4190 it is necessary to act on the mains switch TERMINALS Mains Switch maintaining in the case of single phase onl...

Страница 8: ...n data plate 230V 1N single phase 230V wiring side L1 and L3 connected to the same terminal clamp L1 L2 and N connect to the same terminal clamp 12 Move the jumpers on the voltage change terminal boar...

Страница 9: ...e Use the technical application to check that the device s inputs and outputs function correctly Set the type of connection 3 three phase 1 single phase in the SET UP menu following the procedure prov...

Отзывы: