7  MALFUNCTIONS SHOWN ON THE DISPLAY (FOR THE TECHNICIAN)

 

 

The dishwasher is able to identify a number of malfunctions and show them on the display. If the problem persists after the 
dishwasher has been switched off and back on, proceed as described below: 

 

 

 

Er 04

 

Tank temperature probe 
malfunction 

Tank temperature probe disconnected or not working. 

 

 
 
 

 

Er 05

 

Tank water filling malfunction 

The tank does not fill within the allowed time: check water intake tap, dynamic 
pressure in  intake system, cleaning of  water intake  filter,  possible damage to 
water intake hose or cleaning of rinsing nozzles. 
If  the  problem  persists  during 

“FILL”

:  -  tank  level  switch  failure.  (Always  on 

empty: check whether tank safety pressure switch is tripped). - Leak from pipe 
connected to air trap: if problem persists, check during working programme. - 
Drain  line  vent  valve  fouled:  tank  empties  completely  at  end  of  a  wash 
programme due to siphon effect. 

 

 
 
 

Er 06

 

Water pump-out malfunction 

Inspect  the  filters  dirt  that  the  drain  hose  is  not  blocked,  bent  or  crushed. 
Check that the drain pump is not blocked by dirt by removing the insert on the 
sump (from inside the tank). 
If the problem persist: 
With  the  tank  empty:  tank  pressure  switch  defect  (the  contact  is  locked  on 
full) 
With tank full: drain pump has failed. 

 

 
 
 
 
 

Er 23

 

Boiler does not heat up as expected. 

The  problem might  occur  because water  is  continually entering the  tank  (the 
causes  are  as  for  

“Er  05”  

–  see  above)  If  the  boiler  heating  element  is 

damaged,  this  might  be  due  to  operation  with  no  water  in  the  boiler  -  the 
pressure switch is indicating full even with the boiler empty: - damaged boiler 
heating element – conta ctor failure - open on boiler safety thermostat side. - 
boiler temperature probe faulty or incorrectly positioned  - motherboard relay 
failure, Important: If the boiler heating element is damaged, this might be due 
to operation with no water in the boiler, pressure switch continues to give full 
reading even with boiler empty: check boiler air trap and/or relative pressure 
switch and replace if necessary. 

 

Er 24

 

Boiler temperature probe 
malfunction 

Boiler temperature probe disconnected or not working 

 
 

 

Er 25

 

Boiler water filling malfunction 

The  boiler  does  not  fill  within  the  allowed  time:  check  water  intake  tap, 
dynamic  pressure  in  intake  system,  cleaning  of  water  intake  filter,  possible 
damage to water intake hose or check, in this order: 
-  boiler  pressure  switch  has  failed  (continuous  empty  reading).  -  pipe 
leaking/disconnected (water entering pipe) – item 

“rp” 

in service menu not set 

correctly 

 

 

Er 26

 

Boiler emptying malfunction 

- check that rinsing spray arm nozzles are clean 
- boiler pressure switch has failed (continuous full reading) 

- pipe leaking/disconnected (water entering pipe) 

- rinsing pump not working 

 

 
 

Er 27

 

Boiler emptying malfunction – with 
tank full 
Or boiler full signal on models 
without rinsing pump 

Boiler  pressure  switch  has  failed  (continuous  full  reading)  if  appears  when 
rinsing pump is not present; presence of boiler pressure switch: check setting 
of item 

“rp” 

in service menu 

“rp”

=on for models with rinsing pump 

“rp”

=of for models without rinsing pump 

Содержание CWC 611

Страница 1: ...3 Parameter programming procedure 9 6 4 Modifiable parameters 10 6 5 Adjusting detergent and rinse aid dispensing 10 6 6 Starting the peristaltic pumps in manual mode rapid filling of detergent and rinse aid circuit 11 6 7 Adjusting the regeneration frequency models with softener only 11 6 8 Mains water hardness setting table 11 7 MALFUNCTIONS SHOWN ON THE DISPLAY FOR THE TECHNICIAN 12 8 INSTRUCTI...

Страница 2: ...put you in touch with your nearest authorised Service Centre Our entire product offering can be viewed at 1 3 Declaration of conformity to product standards THIS APPLIANCE IS TAGGED UNDER EUROPEAN DIRECTIVE 2002 96 EC ON WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT WEEE BY MAKING SURE THAT THIS PRODUCT IS DISPOSED OF CORRECTLY THE USER HELPS TO PREVENT POTENTIAL DETRIMENTAL EFFECTS ON HEALTH AND THE ...

Страница 3: ...CT LEANING OR SITTING ON THE OPEN DOOR OF THE DISHWASHER MIGHT CAUSE IT TO TIP OVER PUTTING PEOPLE IN DANGER NEVER LEAVE THE DISHWASHER DOOR OPEN SINCE PEOPLE MIGHT TRIP OVER IT DO NOT DRINK ANY WATER LEFT IN THE DISHES OR DISHWASHER AT THE END OF THE WASHING PROGRAM THE APPLIANCE IS NOT SUITABLE FOR USE BY JUVENILES OR PERSONS WITH REDUCED PHYSICAL SENSORIAL OR MENTAL CAPACITIES OR THOSE WITHOUT ...

Страница 4: ...S FOR BUILT UNDER INSTALLATION KEY TO LETTERS USED IN DIAGRAM R LOWER BACK PANEL Q EARTH TERMINAL P PERISTALTIC PUMP HOSES E ELECTRICITY SUPPLY CABLE S DRAIN HOSE T FILLER HOSE C EXTERNAL DISPENSER POWER SUPPLY CABLE ENTRY POINT ...

Страница 5: ... are suitably protected Place the dishwasher in the chosen point and remove the protective film Level the dishwasher with the aid of a spirit level on its adjustable feet to ensure that it is stable all other mounting solutions must be approved by the manufacturer 4 INSTRUCTIONS FOR TECHNICAL STAFF 4 1 Plumbing hookup PLUMBING HOOKUP The water pipelines and electricity supply cable lead out of the...

Страница 6: ...lor the neutral wire N is blue and the live wires L1 L2 L3 are black grey and brown In the event of single phase connection 230V 1N the connection to the electrical mains must be made using a cable with plug compliant with the relevant regulations THE POWER SUPPLY CABLE IF FITTED MUST BE REPLACED BY THE MANUFACTURER OR AN AUTHORISED SERVICE CENTRE IN ACCORDANCE WITH THE TECHNICAL DATA SPECIFIED ON...

Страница 7: ...r 15 000 wash cycles 5 1 Using the water softener on models with this feature only The quantity of lime in the water which indicates its hardness causes whitish marks on dry dishes and dishes also tend to lose their shine over time The dishwasher is equipped with an automatic water softener which removes the substances that cause hardness from the water with the aid of regenerating salt The first ...

Страница 8: ...must be set or adjusted Control Panel Key to Symbols On off button Total pump out tank boiler button Regeneration button only if softener is fitted Regenerating salt symbol only if softener is fitted Short programme button Medium programme button Long programme button L1 Short programme Led L2 Medium programme Led L3 Long programme Led L4 Resin regeneration Led only if softener is fitted L5 Draina...

Страница 9: ...washing pump in operation Tank temperature Rinsing phase programme running washing pump stopped Boiler temperature Programming phase See parameter programming section Error message See error messages section 6 2 Note on display of temperatures Temperatures shown on the display might not indicate the actual temperature in the tank and or boiler during heating wait about 1 after the heating elements...

Страница 10: ...On OF Thermostop On enabled OF disabled Sr Access Service menu for Authorised Engineer only 6 5 Adjusting detergent and rinse aid dispensing WARNING Ensure that the appliance is not powered up ELECTRIC SHOCK HAZARD RD Detergent dispensing regulator screw OPTIONAL RB Rinse aid dispensing regulator screw Important If the pump does not deliver rinse aid check the valve inside A unscrew anti clockwise...

Страница 11: ... minutes and then also take in detergent for the last 2 6 7 Adjusting the regeneration frequency models with softener only See appliance setup menu point 6 4 With values over 60 dF an external water treatment device must be used and the regeneration frequency must be set at H0 6 8 Mains water hardness setting table This table shows the relationship between the intake water hardness and the quantit...

Страница 12: ...ler heating element is damaged this might be due to operation with no water in the boiler the pressure switch is indicating full even with the boiler empty damaged boiler heating element conta ctor failure open on boiler safety thermostat side boiler temperature probe faulty or incorrectly positioned motherboard relay failure Important If the boiler heating element is damaged this might be due to ...

Страница 13: ...rogramme Led L3 Long programme Led L4 Resin regeneration Led only if softener is fitted L5 Drainage Led L6 Appliance on Led L7 No salt Led only if softener is fitted CLOSE Close the door FILL Machine preparing for cycle End End of operation requested PrF 600 Appliance model displayed when the appliance is switched on with the master switch UnLoad Pump out 8 INSTRUCTIONS FOR THE USER 8 1 Control pa...

Страница 14: ...llow reuse 8 2 Before washing Use only detergents and rinse aids for industrial dishwashers Do not use detergents intended for hand washing We recommend the use of Smeg products specially developed for this dishwasher When topping up the tanks take care not to swap the products this might damage the dishwasher and cause malfunctions Do not mix different detergents this would damage the dispenser d...

Страница 15: ...wo digits on the display light up With the door closed filling of the tank begins The word FILL scrolls across the display and the Led on will be that of the latest program set The display shows End when the tank is full Load the dishes and close the door Select the program required by holding down one of the three buttons required for about 2 the Led of the program flashes While washing is in pro...

Страница 16: ...emperature and the Thermostop setting 8 5 Changing the program If the master switch is not turned off the appliance sets on the last programme performed To change it press the key of the program required the Led comes on To confirm hold down for about 2 The Led starts to flash and the washing programme starts If a programme is already running it can be changed by first switching the appliance to p...

Страница 17: ...sh cycles see point 6 8 of the technical manual is reached the Led above the button flashes Therefore during the working day resin regeneration must be carried out following the procedure described below There are 2 regeneration modes 1 ON REQUEST Press the button for 5 to start regenerating the Led flashes and the regeneration phase starts It lasts about 10 minutes during which time the Led keeps...

Страница 18: ...en put them correctly back in place do not use sharp or pointed tools Clean away any limescale deposits to prevent excessive build ups 9 2 Routine inspection of the spray arms once a week Remove the washing and rinsing top and bottom spray arms by unscrewing the central ring nut 1 remove the parts of the rinsing spray arms 3 by taking out the screws 2 with a screwdriver as shown below Do not unscr...

Страница 19: ... the after sales service if less than 50 C Inappropriate programme set Increase wash programme duration especially if dirt has dried on Inadequate rinsing Dynamic pressure of mains water insufficient Spray arm nozzles fouled Limescale in boiler Check mains water pressure Check that water intake filter is not fouled Clean rinsing nozzles If you are unable to solve the problem call the after sales s...

Страница 20: ... blocked bent or crushed Check that the drain pump is not blocked by dirt by removing the insert on the sump from inside the tank If the problem persist With the tank empty tank pressure switch defect the contact is locked on full With tank full drain pump has failed Er 23 Boiler heating malfunction does not heat up Contact the After Sales Service Er 24 Boiler temperature probe malfunction Contact...

Отзывы: