6.6 Starting the peristaltic pumps in manual mode – rapid filling of detergent and rinse
aid circuit
With the dishwasher powered up and the tank full, press the buttons simultaneously for 5”
The peristaltic pumps continue to operate until one of the 2 buttons is pressed again; the lights remain on as long as the pumps
are running. The display shows
“r d” .
Bear in mind that the rinse aid peristaltic pump fills the circuit in about 7 minutes, while
for the detergent it only takes 2 minutes. So draw only rinse aid from the jerry cans (1 for the rinse aid and the other for the
detergent) for the first 5 minutes and then also take in detergent for the last 2.
6.7 Adjusting the regeneration frequency (models with softener only)
See appliance setup menu (point 6.4)
With values over 60°dF an external water treatment device must be used and the regeneration frequency must
be set at H0
6.8 Mains water hardness setting table
This table shows the relationship between the intake water hardness and the quantity the resins are able to treat;
regeneration is required once the appliance has performed the set number of cycles. Regeneration cycle duration: 12
minutes.
Hardness
(°dH German degrees)
Hardness
(°dF French degrees)
Setting
level
Resin regeneration interval:
approximate number
of wash cycles
Regeneration off
Regeneration off
H0
8.5
15
H1
152
11
20
H2
128
17
30
H3 default
74
22.5
40
H4
37
28
50
H5
27
33.5
60
H6
11