Instructions for the installer
3.
ADAPTATION TO DIFFERENT TYPES OF GAS
Before carrying out the following operations, disconnect the appliance
from the electricity supply
The cooker hob is preset for
natural gas G20
(2H) at a pressure of 20
mbar. In the case of functioning with other types of gas the burner
nozzles must be changed and the minimum flame adjusted on the gas
taps. To change the nozzles, proceed as described below.
3.1
Replacement of nozzles on the hob
This operation requires no primary air regulation.
1.
Extract the pan stands and remove all the caps and flame-spreader
crowns;
2.
Unscrew the burner nozzles with a 7 mm socket wrench;
3.
Replace the nozzles according to the type of gas to be used and the
description in paragraph “3.2 Burner and nozzle characteristics
table”.
Replace the burners in the correct position.
43