![Smeg Classica C6IPX9-1 Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/smeg/classica-c6ipx9-1/classica-c6ipx9-1_original-instructions-manual_1301473049.webp)
Installation
51
EN
•
220-240 V 3
~
4 x 6 mm²
four-core
cable.
•
220-240 V 1N
~
3 x 10 mm²
three-core
cable.
•
380-415 V 2N
~
4 x 6 mm²
four-core
cable.
•
380-415 V 3N
~
5 x 2.5 mm²
five-core
cable.
Access to the terminal board
To connect the power supply cable, you
must access the terminal board on the rear
casing:
1. Remove the screws fastening the plate to
the rear casing.
2. Gently rotate the plate and remove it
from its seat.
The values indicated refer to the
cross-section of the internal
conductor.
The aforementioned power cables
are sized taking into account the
coincidence factor (in compliance
with standard EN 60335-2-6).