Instructions for the installer
20
14.
INSTALLATION
14.1
Technical information
Appliance type
See rating plate
Electrical
connections
220 - 240V~ 50Hz / 220 - 240V 2
∼
/ 380 - 415V 2N
∼
Required protection fuse for the oven
30 Amps
Hob
rating
Gas
Oven
rating
Electric
Maximum electrical power
5.38 kW
Small oven grilling rating
Electric
Small grill power
1.85 kW (230 V)
Large grill power
2.65 kW (230 V)
Ovens lightings
25 W
(230 V)
Large oven
Small oven
OVEN CAVITY DIMENSIONS
Height
(cm)
34
17
Width
(cm)
41
41
Depth
(cm)
40
41
Internal
volume
(cm
2
) 55760
28577
14.2
The rating plate
CHECK THAT THE VOLTAGE AND DIMENSIONING
OF THE SUPPLY LINE CORRESPOND TO THE
CHARACTERISTICS SHOWN ON THE PLATE
FIXED TO THE REAR PROTECTIVE COVER OF
THE APPLIANCE.
THIS PLATE MUST NEVER BE REMOVED.
14.3
Electrical connection
IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE
METHODS REQUIRED BY SAFETY RULES.
WHEN LINKING UP TO MAINS BY PLUG AND SOCKET, MAKE SURE THAT BOTH ARE
COMPATIBLE AND CONNECT BY MEANS OF A POWER CABLE COMPLYING WITH
APPLICABLE REGULATIONS.
THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN.
NEVER UNPLUG BY PULLING ON THE CABLE.
IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE OVEN,
FOLLOWING THE INSTRUCTIONS. SHOULD THE APPLIANCE NOT FUNCTION, DISCONNECT
IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE.
NEVER ATTEMPT TO REPAIR THE APPLIANCE.
IF A PLUG AND SOCKET CONNECTION IS BEING USED MAKE SURE THAT THE PLUG AND
SOCKET ARE COMPATIBLE. AVOID USE OF ADAPTERS AND SHUNTS AS THESE COULD
CAUSE OVERHEATING AND RISK OF BURNS.
IF A FIXED CONNECTION IS BEING USED FIT POWER LINE WITH AN OMNIPOLAR CIRCUIT
BREAKER WITH A CONTACT OPENING GAP EQUAL TO OR GREATER THAN
3 MM
IN AN
EASILY ACCESSIBLE POSITION IN PROXIMITY TO THE OVEN.
Содержание CC62MFX5