Instructions for the installer
41
3.3
Burner and nozzle characteristics table (90 cm model)
Burner
Rated
heating
capacity
(kW)
LIQUID GAS
–
G30/G31
30/37
mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary
1
50
30
350
73
71
Semi-rapid
1.8
65
33
450
131
129
Rapid
3
85
45
800
218
214
Triple crown (4)
3.2
91
65
1500
233
229
Triple crown (8)
3.5
94
65
1500
255
250
Fish kettle
1.9
68
45
800
138
136
Oven
3.2
87
50
900
233
229
Maxi oven
5.2
110
59
1300
378
372
Grill
2.9
87
//
//
211
207
Maxi grill
4.0
100
//
//
291
286
Burner
Rated
heating
capacity
(kW)
CITY GAS
–
G110
8
mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary
1
145
350
Semi-rapid
1.8
185
450
Rapid
3
260
800
Triple crown
3.5
290
1200
Fish kettle
1.9
190
800
Gas G110 cannot be used in gas oven models.
The values for city gas refer to appliances in category III 1a2H3+.
Burner
Rated
heating
capacity
(kW)
NATURAL GAS
–
G20
20
mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary
1
72
350
Semi-rapid
1.8
97
450
Rapid
3
115
800
Triple crown (4)
3.5
133
1500
Triple crown (8)
3.5
140
1500
Fish kettle
1.9
94
800
Oven
3.2
130
850
Maxi oven
5.2
164
1200
Grill
2.9
130
//
Maxi grill
4.0
150
//
Содержание CA61VM
Страница 30: ......
Страница 31: ...914772033 E ...