Instructions for the installer
36
2.1
Electrical connection
Make sure the voltage and the cross-section of the power supply line match the specifications
indicated on the identification plate positioned in the storage compartment.
Do not remove this plate for any reason.
If the appliance is connected to the power supply network by means of a fixed connection, install a
multipolar cut-out device on the power supply line, with a contact opening distance equal to or
greater than
3 mm,
located near the appliance and in an easily reachable position.
Connection to the power supply network may be fixed or with a plug and socket. In the latter case
the plug and socket must be suitable for the cable employed and conform to the regulations in force.
Regardless of the type of connection, the appliance must be earthed. Before connection, make sure
that the power supply line is suitably earthed. Avoid the use of adapters and shunts.
1 - For operation on 220-240V
∼
:
use a three-pole cable of the
H05RR-F or H05V2V2-F type:
3 x 2.5 mm
2
(for 90 cm models)
3 x 1.5 mm
2
(for 50 and 60 cm models).
2 - For operation on 380-415V2N
∼
(only for 90 cm models):
use a four-pole cable of the H05RR-F or H05V2V2-F type
(cable with a cross-section of 4 x 1.5 mm
2
)
3 - For operation on 380-415V3N
∼
(only for 90 cm models):
use a five-pole cable of the H05RR-F or H05V2V2-F type
(cable with a cross-section of 5 x 1.5 mm
2
)
The end to be connected to the appliance must have an earth
wire (yellow-green) at least 20 mm longer than the others.
WARNING: THE VALUES INDICATED ABOVE REFER TO THE CROSS-SECTION OF THE
INTERNAL CONDUCTOR.
Warning: only some of the 90 cm models can be connected with two or three phases.
2.2
Room ventilation
The room containing the appliance should have a permanent air supply in accordance with the
standards in force. The room where the appliance is installed must have enough air flow for the
regular combustion of gas and for the air exchange needed in the room itself. The air vents,
protected by grills, must be suitably dimensioned in compliance with the current regulations and
positioned so that no part of them is obstructed.
The cooker must be kept adequately ventilated in order to eliminate the heat and humidity produced
by cooking: in particular, after prolonged use, you are recommended to open a window or to
increase the speed of any fans.