6.4 Magnetism Switch Control

 

1.

 

Press the “POWER” key and switch  on the  power supply to the SMD rework 

system.   

2.

 

If  the  LCD  does  not  display  “

”,  it  means  the  system  is  completely 

controlled by the magnetism switch. As when taking down the handle from the 

holder,  the  system  comes  into  the  working  state.  At  the  moment,  the  pedal 

switch has no effect. 

3.

 

When the handle is took down from the handle holder

, the system comes to 

work in the current work  channel until the  work time ends. At the  moment, it 

can press any key (except “POWER” and “INFO” keys) to return work mode. 

4.

 

If  putting  the  handle  on  the  handle  holder,  the  system  will  come  into  the 

sleeping state at once. 

5.

 

When  working in the lock state,

 the  LCD displays “ ”. At the  moment, the 

system only can work in the 

CH1

 channel, and cannot switch the channel and 

change parameter values. 

6.

 

When  working  in  the  unlock  state,

  the  LCD  displays  “ ”.  At  the  moment, 

whatever  is  in  the  work  state  or  in  the  sleeping  state,  the  system  can  switch 

channel and change parameter values, and work in the different channel “CH0” 

or  “CH1”  or “CH2”  or “CH3”with  different  parameter  values.  The  parameter 

values setting method is as following: 

a)

 

Press “CH1” or “CH2” or “CH3” key to switch the current work channel. 

Press  any  key  (except  “POWER”  or  “INFO”  or  “CH1”  or  “CH2”  or 

“CH3”  key)  to  the  “CH0”  channel  with  current  parameter  values.  For 

example,  if  pressing  “CH0”  key,  the  system  will  work  at  the  “CH0” 

channel. 

b)

 

The  system  can  work  at  the  different  channel  with  different  parameter 

values  which  including  temperature,  time  and  airflow.  The  setting 

methods are as followings: 

 

Press  TEMP  “

”  or  “

”  key  to  set  the  temperature  and  the 

temperature  range  is  100

~500

.  The  setting  method  refers  to 

“6.1 temperature setting”. 

 

Press AIR “

” or “

” key to set the airflow and the airflow range is 

6~200. The setting method refers to “6.2 airflow setting”. 

 

Press “INFO” and AIR “

” or “

” keys at the same time to set the 

work  time  and  the  time  range  is  1~999seconds.  The  setting  method 

refers to “6.3 work time setting”. 

c)

 

All the  parameter  settings  work  in the  “CH0”  channel.  When  setting  the 

values  of  temperature  or  time  or  airflow,  the  “CH0”  will  be  the  current 

channel and the setting values will be saved into the “CH0” channel. 

d)

 

If  need  to  set  the  channel  “CH1”  or  “CH2”  or  “CH3”  with  different 

parameter values, press “SAVE” key not loosely and then press “CH1” or 

“CH2”  or “CH3”  key  about  one  seconds to  save  the  parameter  values in 

the  “CH0”  channel  to  the  corresponding  channel  “CH1”  or  “CH2”  or 

“CH3”. 

 

6.5 Pedal Switch Control 

1.

 

Press  the  POWER  key  and  switch  on  the  power  supply  to  the  SMD  rework 

system. 

2.

 

If  the  LCD  displays  “

”,  it  means  the  system  is  controlled  by  the  pedal 

switch when taking down the handle from the holder.   

5.

 

Spring  the  pedal  in  the  work  state  and  then  the  system  comes  to the  sleeping 

state. 

6.

 

Spring  the  pedal  switch  not  loosely  in  the  sleeping  state  and  then  the  system 

comes  to  the  work  state.  The  time  parameter  window  will  display  “---”,  it 

means the system will be in the work mode until loosing the pedal switch. 

7.

 

Spring the pedal switch and then loose in the sleeping state, the system comes 

to  work  in  the  current channel  which  the  LCD displaying.  Till the  work  time 

window  displaying  “OFF”,  the  system  cools  down  to  100

  and  then  into 

sleeping state. 

8.

 

When  working  in  the  lock  state,  the  LCD  displays  “ ”.  At  the  moment,  the 

system  only can  work in the CH1 channel, and cannot switch the  channel and 

change parameter values. 

Page7 

Page8 

Содержание 856AE

Страница 1: ...Thank you for purchasing our SMD Rework station The unit is exclusively designed for reworking and soldering SMD component Please carefully read this manual before operating the unit Store this manua...

Страница 2: ...truction 5 6 1 Temperature setting 5 6 2 Work time setting 6 6 3 Airflow setting 6 6 4 Magnetism Switch Control 7 6 5 Pedal Switch Control 8 Sleeping 9 7 1 How into the Sleeping State 9 7 2 Resume 10...

Страница 3: ...the power cord when not in use for a long time 9 Handle with care not to shock the unit sharply 10 A periodically maintenance of the unit is necessary 11 Don t operate the unit with wet hand or when...

Страница 4: ...nt pins must insert into heater localizer and the sensor pins into the sensor localizer CHARACTERISTIC 1 There are three programmable channels CH1 CH2 CH3 and it can set the working time airflow and t...

Страница 5: ...password setting and return to the menu setting d If the secondary inputting password is same with the first inputting password the password setting is successful The new password will flash three tim...

Страница 6: ...etting The setting method refers to 6 1 temperature setting There are three times to input the password only when the inputting password is right the system runs into the menu setting process Or else...

Страница 7: ...t setting temperature If pressing TEMP key not loosely at least one second the setting temperature will drop rapidly Loose the TEMP key until down to the needed temperature 7 2 Resume 1 When the handl...

Страница 8: ...tate In the sleeping state the LCD will display and 6 2 Airflow Setting Raise Airflow Click AIR key and then the airflow grade will rise 1 and the LCD displays the current setting airflow grade If pre...

Страница 9: ...he temperature and the temperature range is 100 500 The setting method refers to 6 1 temperature setting Press AIR or key to set the airflow and the airflow range is 6 200 The setting method refers to...

Отзывы: