The current work channel.
:
When the LCD displays “set”, it means the unit is in the menu setting state
and the handle and suction pen cannot work at the state.
:
When LCD displays this mark, it means the pedal switch can control the unit
in work state or sleeping state after taking down the handle from the holder.
:
It means the unit is in the sleeping state.
:
Lock the parameter values setting and only can work in the current channel
and parameters.
: Switch the work channels and setting parameter values.
:
When LCD displays this mark, it will give sound when pressing keys.
: When LCD displays this mark, it means the unit is in the password
inputting state.
: When LCD displays this mark, it means the unit is in the password
changing state.
Ⅵ
. OPERATION INSTRUCTION
Firstly, place the SMD rework system on the workbench. And then connect well the
power cord and other connection lines. Place the handle on the handle holder
before switching on the power supply.
6.1 Temperature Setting
Raise temperature:
Click
“TEMP
▲
”
key and then the temperature will rise
1℃
, and the LCD displays the current setting temperature.
If pressing
“
TEMP
▲”
not loosely at least one second, the
setting temperature will rise rapidly. Loose the “TEMP
▲
”
key until up to the needed temperature.
Reduce
temperature
:
Click
“TEMP
▼
”
key and then the temperature will drop
1℃
, and the LCD displays the current setting temperature.
If pressing “TEMP
▼
” key not loosely at least one second,
the setting temperature will drop rapidly. Loose the “TEMP
▼
” key until down to the needed temperature.
7.2 Resume
1.
When the handle is putting on the handle, it cannot be resumed from sleeping.
2.
If the unit is in sleeping when the handle on the holder, take down the handle
from the holder. At the time, it will work at once if it is controlled by the
magnetic switch. Or else, it will work after click the pedal switch.
3.
If the handle is not on the holder in sleeping:
If the unit controlled by the
magnetic switch, click any keys except “POWER” and “INFO” keys to work.
Or else, click the pedal to. In work state,
will not display.
Ⅷ
. Calibration
Methods of recalibrating the temperature are as followings:
1. In work state, set the calibration temperature 300
℃
.
2. When the temperature is stable, test the outlet temperature of the handle with
thermometer and write down it.
Into the calibration mode:
Press TEMP “
▲
”, “
▼
”, “INFO”
和
“SAVE”
four keys at the same time, the system will enter into the temperature
calibrating mode and the LCD will display “
---”.
3. And then the hundreds digit twinkle, press “
▲
”or “
▼
” key to input the
temperature testing by the thermometer. Inputting method refers to “6.1
temperature setting”.
4.
In the work mode, when the temperature is stable (300
℃
), test the outlet
temperature again with the thermometer. If the temperature still has some
departure, you can repeat calibration according with the above steps.
Note: * Suggest using 191 or 192 thermometer to measure the temperature.