How to Order
Series
VP300/500/700
Rubber Seal
3 Port/Pilot Poppet Type
Body Ported/Single Unit
VP 3 4 2
5 G
1 01
A
Series
3
5
7
VP300
VP500
VP700
5
6
24 VDC
12 VDC
Pilot type
—
R
Internal pilot
External pilot
Bracket
—
F
Without bracket
With bracket
Thread type
—
F
N
T
Rc
G
NPT
NPTF
Light/surge voltage suppressor
DC
AC
—
S
Z
R
U
Without light/surge voltage suppressor
With surge voltage suppressor
With light/surge voltage suppressor
With surge voltage suppressor (Non-polar)
With light/surge voltage suppressor (Non-polar)
Port size
01
02
03
04
Symbol Port size
VP300
1/8
1/4
3/8
1/2
VP500 VP700
Manual override
—:
Non-locking
push type
D
:
Push-turn locking
slotted type
E
:
Push-turn locking
lever type
Pressure specification
—
K
Standard (0.7 MPa)
High-pressure type (1.0 MPa)
Electrical entry
Grommet
Conduit
terminal
L-type plug
connector
M-type plug
connector
DIN
terminal
DIN
(EN175301-803)
terminal
G
: Lead wire
length 300 mm
H
: Lead wire
length 600 mm
L
: With lead wire
(length 300 mm)
LN
:
Without lead wire
LO
:
Without connector
M
: With lead wire
(length 300 mm)
D
: With connector
Y
: With connector
T
: Conduit
terminal
DO
:
Without connector
YO
:
Without connector
MN
:
Without lead wire
MO
:
Without connector
G
: Lead wire
length 300 mm
H
: Lead wire
length 600 mm
DC
Without light/
surge voltage
suppressor
Coil specification
—
T
Standard
With power saving circuit (DC only)
Body ported
Note 1) Be sure to select the power sa-
ving circuit type when it is conti-
nuously energized for a long ti-
me.
(Refer to back page 7 for de-
tails.)
Note 2) T type is only available for DC
mode. When T is selected, only
Z type of light/surge voltage
suppressor is available.
(Note that when the electrical
entry of DIN terminal type wit-
hout connector is selected, only
DOS and YOS are available.)
Note 1) There is no S option for AC mode, since a rectifier prevents
surge voltage generation.
Note 2) In the DIN terminal type, since a light is installed in the con-
nector, DOZ, DOU, YOZ, YOU are not available.
Rated voltage
DC
1
2
3
4
7
100 VAC
200 VAC
110 VAC [115 VAC]
220 VAC [230 VAC]
240 VAC
AC (50/60 Hz)
When using the surge voltage suppressor type,
residual voltage will remain. Refer to back page 7
for details.
Caution
Note 1) LN and MN types are with 2 sockets.
Note 2) Refer to back page 4 when different length of lead wire for L/M-type plug connector is required.
Note 3) Refer to back page 5 for details on the DIN (EN175301-803) terminal.
Note 4) The AC mode of G, H, L and M types are not CE compliant.
[IP65 compatible] [IP65 compatible] [IP65 compatible]
Type of actuation
A
B
N.C. (Normally closed)
N.O. (Normally open)
Made to Order
—
X500
—
Pilot exhaust port with piping thread (M3)
specification (Refer to page 24).
Note) Only DIN and conduit terminal types
are available for AC mode.
Refer to the electrical entry for details.
Note 1)
Note) Only DIN and conduit terminal
types can be set for AC mode. Refer
to the electrical entry for details.
Low power consumption 1.5 W (DC)
Possible to use as either a
selector or divider valve
Possible to change from
N.C. to N.O.
Possible to use in vacuum
applications
Up to –100 kPa
Use external pilot type in the following
cases:
• For vacuum or for low pressure: 0.2 MPa
or less.
• Please consult SMC for use in a vacuum
hold application.
• When having P port downsized in diameter
• When using A port as the atmospheric
releasing port, e.g. air blower.
External Pilot
Specifications
Solenoid Specifications
Response Time
Electrical entry
Coil rated voltage (V)
Allowable voltage fluctuation
Power consumption (W)
Apparent power
(VA)
Note 1)
Surge voltage suppressor
Indicator light
24, 12
100, 110, 200, 220, 240
±
10% of rated voltage
∗
Diode (Non-polar type: Varistor)
LED (Neon bulb is used for AC mode of D, Y, T.)
1.5 (With light: 1.75)
0.75 (With light only)
1.55 (With light: 1.7)
1.5 (With light: 1.55)
0.55 (With light only)
1.55 (With light: 1.65)
Grommet (G), (H)
L-type plug connector (L)
M-type plug connector (M)
DIN terminal (D)
DIN (EN175301-803) terminal (Y)
Conduit terminal (T)
DC
AC (50/60 Hz)
Standard
With power saving circuit
100 V
110 V
[115 V]
200 V
220 V
[230 V]
240 V
G, H, L, M
D, Y, T
Note 1)
It is in common between 110 VAC and 115 VAC, and between 220 VAC and 230 VAC.
Note 2)
Allowable voltage fluctuation is –15% to +5% of the rated voltage for 115 VAC or 230 VAC.
Note 3)
Since voltage drops due to the internal circuit in S, Z, T types (with power saving circuit), the
allowable voltage fluctuation should be within the following range.
24 VDC: –7% to +10%
12 VDC: –4% to +10%
Fluid
Type of actuation
Internal pilot
Operating pressure range (MPa)
External pilot
Operating pressure range (MPa)
Ambient and fluid temperature (
°
C)
Max. operating frequency (Hz)
Manual override
Pilot exhaust type
Lubrication
Mounting orientation
Impact/Vibration resistance (m/s
2
)
Note)
Enclosure
Standard
High-pressure type
Standard
High-pressure type
Pilot pressure range
Note) Impact resistance: No malfunction occurred when it is tested in the axial direction and at the right
angles to the main valve and armature in both energized and de-energized states
every once for each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was
performed at both energized and de-energized states in the axial direction and at
the right angles to the main valve and armature. (Values at the initial period)
VP342
VP542
VP742
Standard (0.2 to 0.7)
High-pressure type (0.2 to 1.0)
Standard (0.2 to 0.7)
High-pressure type (0.2 to 1.0)
Standard (0.2 to 0.7)
High-pressure type (0.2 to 1.0)
Response time ms (at 0.5 MPa)
13 or less
17 or less
14 or less
18 or less
19 or less
22 or less
Without light/surge
voltage suppressor
With light/surge voltage suppressor
S, Z type
38 or less
42 or less
39 or less
43 or less
44 or less
47 or less
R, U type
16 or less
20 or less
17 or less
21 or less
22 or less
25 or less
AC
38 or less
42 or less
39 or less
43 or less
44 or less
47 or less
Note) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20
°
C, at rated voltage)
Pressure specifications
Model
DC
AC
Series VP300
Series VP500
Series VP700
Made to Order
(Refer to page 24 for details.)
Pilot exhaust port with piping
thread (M3) specification
X500
Air
N.C. or N.O. (Convertible)
0.2 to 0.7
0.2 to 1.0
–100 kPa to 0.7
–100 kPa to 1.0
Same as operating pressure (Min. 0.2 MPa)
–10 to 50 (No freezing)
5
Individual exhaust
Not required
Unrestricted
300/50
Dust-tight (IP65 for D, Y, T)
Non-locking push type
Push-turn locking slotted type
Push-turn locking lever type
• Refer to back page 8 for
changing the type of actuation.
Series
VP300/500/700
Pilot Poppet Type
Body Ported/Single Unit
1