1P
1P
1P
1P
+
–
3R
3R
18.5
28
1/4
3(R) port
(Pitch)
P = 27.5
NO
NC
96.1
57.6
26
.2
Approx. 300
(Lead wire length)
96.1
57.6
26
.2
28
7.5
L
2
L
1
(Station n)
(Station 1)
N.C.
N.O.
2 x ø6.5
(For mounting)
Manual override
(Pitch)
P = 27.5
+
–
2A
2A
50.1
80.2
28
57.2
37.5
11
(Indicator light)
1/4
2(A) port
(Pitch)
P = 27.5
80.2
51.5
Approx. 300
(Lead wire length)
97.3
120.2
111.2
Max. 10
102.9
Applicable cable O.D.
ø4.5 to ø7
Pg9
80.2
57.5
102.4
Approx. 300
(Lead wire length)
91.2
Approx. 300
(Lead wire
length)
94
88.9
Max. 10
105.3
124.4 [114.4]
114.4 [104.4]
Pg9
(Indicator light)
Applicable cable O.D.
ø4.5 to ø7
1P
1P
72.5
30.5
24
50
13
.5
17.5
M5 x 0.8
Common external pilot port
(External pilot specification: R)
PE port
Note)
(ø3.8)
1/4
1(P) port
Note) Refer to page 24 when piping to PE
port is required.
Station n
L
1
L
2
2
83.5
68.5
111
96
138.5
123.5
166
151
193.5
178.5
221
206
248.5
233.5
276
261
303.5
288.5
331
316
358.5
343.5
386
371
413.5
398.5
441
426
468.5
453.5
496
481
523.5
508.5
551
536
578.5
563.5
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19
20
Type 42/Individual exhaust: VV3P3-42
- 3-02
Grommet (G)
Stations
Series VP300/Dimensions
Grommet (G)
DC without light/surge voltage
suppressor
DIN terminal (D, Y)
M-type
plug connector (M)
L-type
plug connector (L)
Conduit terminal (T)
Unless otherwise indicated, dimensions are the same as Grommet (G).
[ ] valves: Without indicator light
Series
VP300/500/700
3R
1P
3R
1P
3R
1P
3R
1P
92.5
63.8
Approx. 300
(Lead wire length)
123.5
132.5
123.5
Max. 10
129.1
Pg9
Applicable cable O.D.
ø4.5 to ø7
103.5
Approx. 300
(Lead wire
length)
120.2
115.1
92.5
69.8
Approx. 300
(Lead wire length)
128.6
NO
NC
31
7.5
L
2
L
1
Approx. 300
(Lead wire length)
122.3
83.8
41.1
122.3
83.8
41.1
(Pitch)
P = 33
N.C.
N.O.
(Station 1)
(Station n)
2 x ø7.2
(For mounting)
Manual override
+
–
2A
2A
61.3
31
92.5
69.5
47.5
13.5
(Pitch)
P = 33
(Indicator light)
3/8
2(A) port
136.7 [126.7]
126.7 [116.7]
Max. 10
131.5
Pg9
(Indicator light)
Applicable cable O.D.
ø4.5 to ø7
3R
1P
3R
1P
23.5
60
33
42
30
20.5
PE port
Note)
(ø3.8)
M5 x 0.8
Common external pilot port
(External pilot specification: R)
3/8
1(P), 3(R) port
Note) Refer to page 24 when piping to PE
port is required.
Station n
L
1
L
2
2
95
80
128
113
161
146
194
179
227
212
260
245
293
278
326
311
359
344
392
377
425
410
458
443
491
476
524
509
557
542
590
575
623
608
656
641
689
674
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19
20
Grommet (G)
DC without light/surge voltage
suppressor
DIN terminal (D, Y)
M-type
plug connector (M)
L-type
plug connector (L)
Conduit terminal (T)
Unless otherwise indicated, dimensions are the same as Grommet (G).
[ ] valves: Without indicator light
Series VP500/Dimensions
Type 41/Common exhaust: VV3P5-41
- 1-03
Grommet (G)
Stations
Series
VP300/500/700
Pilot Poppet Type
Common Exhaust
Type 41
/Individual Exhaust
Type 42
19