AC (
Z) circuit
DC (
U) circuit
NL: Neon bulb, R: Resistor
LED: Light emitting diode, R: Resistor
LED
R
NL
R
LED: Light emitting diode
D: Protective diode
R: Resistor
DC (
Z) circuit
D
LED
–
+
R
(–)
(+)
Set screw
Tightening torque
0.5 to 0.6 N·m
Terminal block
cover
Tightening torque
0.5 to 0.6 N·m
Terminal screw
(2 locations)
Tightening torque
0.5 to 0.6 N·m
Grommet
(Rubber)
Washer
Ground nut
Tightening torque
2.5 to 3.75 N·m
Y type
D type
11
10
5.5
8.5
Ground terminal
screw
How to Order DIN Connector
Caution
Caution
Without indicator light:
DC, AC, Other voltages:
V200-
-1
With indicator light:
DC
Polar type (
Z)
:
V200-
-3-
Non-polar type (
U) :
V200-
-5-
AC (
Z)
:
V200-
-7-
Rated voltage
01
02
07
100/110 VAC [115 VAC]
200/220 VAC [230 VAC]
240 VAC
Rated voltage
05
06
24 VDC
12 VDC
Circuit with indicator light (Built-in connector)
How to Use Conduit Terminal
Connection
1) Loosen the set screw and remove the terminal block cover
from the terminal block.
2) Loosen the terminal screws on the terminal block, insert the
core of the lead wire or crimped terminal
into the terminal, and attach securely with
the terminal screws.
In addition, when using the DC mode type
with a surge voltage suppressor (polar: S
and Z types), connect wires to terminal 1
and 2 corresponding to the polarity (+ or –)
as shown on the figure on the right.
3) Secure the cord by fastening the ground nut.
DIN (EN175301-803) Terminal
Y type DIN terminal corresponds to the DIN connector with
terminal pitch 10 mm, which complies with EN175301-803B.
Since the terminal pitch is different from the D type DIN
connector, these two types are not interchangeable.
Connector specification
61
63
D type
Y type
In case of connecting wires, select cabtire cords carefully becau-
se if those out of the specified range (ø4.5 to ø7) are used, it will
not be able to satisfy IP65 (enclosure).
Tighten the ground nut and set screw within the specified range
of torque.
Applicable cable
Cable O.D.: ø4.5 to ø7.
(Reference) 0.5 mm
2
to 1.5 mm
2
, 2-core or 3-core, equivalent to
JIS C 3306.
Applicable crimped terminal
O terminal: Equivalent to R1.25-3 that is specified in JIS C 2805.
Y terminal: Equivalent to 1.25-3, which is released by JST Mfg.
Co., Ltd.
Note) Use O terminal when a ground terminal is used.
Series
VP
Specific Product Precautions 3
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
(–) (+)
(+) (–)
Varistor
(–) (+)
(+) (–)
Varistor
LED
Red (+)
Black (–)
Red (+)
Black (–)
Polarity protection diode
Coil
Coil
Coil
Coil
Coil
Coil
Diode
Polarity protection diode
LED
Diode
For DIN type, installed
in the connector
Diode
Polarity protection diode
LED
(–)
(+)
For DIN type, installed
in the connector
LED
Varistor
(+) (–)
(–) (+)
Caution
• Please connect correctly the lead wires to + (positive) and –
(negative) indications on the connector. (For non-polar type, the
lead wires can be connected to either one.)
• When the valve with mis-wiring protection diode is used, the
voltage will drop by approx. 1 V. Therefore, pay attention to the
allowable voltage fluctuation (For details, refer to the solenoid
specification of each type of valve).
• Solenoids, whose lead wires have been pre-wired: + (positive)
side red and – (negative) side black.
<DC>
Polar type
With surge voltage suppressor (
S)
DIN or Conduit terminal
With light/surge voltage suppressor (
Z)
DIN or Conduit terminal
With light/surge voltage suppressor (
U)
Non-polar type
With surge voltage suppressor (
R)
Grommet or L/M-type plug connector
With light/surge voltage suppressor (
U)
Grommet or L/M-type plug connector
With light/surge voltage suppressor (
Z)
Light/Surge Voltage Suppressor
Switching element
C
OFF
Leakage current
Leakage
voltage
Valve
R
Power
DC coil
AC coil
Especially when a resistor and a switching element are used
in parallel or C-R device (surge voltage suppressor) is used
for the protection of the switching device, note that leakage
voltage will be increased by passing leakage voltage through
the resistor and C-R device. Therefore, suppressor residual
leakage voltage should be as follows.
3% or less of the rated voltage
8% or less of the rated voltage
Leakage Voltage
Caution
If a valve is continuously energized for long periods of time,
the rise in temperature due to heat-up of the coil assembly
may cause a decline in solenoid valve performance, reduce
service life, or have adverse effects on peripheral equipment.
If the valve is continuously energized for a long time, or the
total energizing time per day becomes longer than the non-
energizing time, use a valve with power saving circuit.
Also, it is possible to reduce the energizing time by using a
N.O. (normally open) valve.
When the valve is mounted onto a control panel, take
measures against radiation in order to keep the valve
temperature within the specified range.
Continuous Duty
Caution
Series
VP
Specific Product Precautions 4
Be sure to read before handling.
Refer to back pages 1 and 2 for Safety Instructions, “Handling Precautions for SMC
Products” (M-E03-3) for 3/4/5 Port Solenoid Valves Precautions.
Back page 6