![SMC Networks PFG3 0 Series Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/smc-networks/pfg3-0-series/pfg3-0-series_operation-manual_1299985026.webp)
-25-
No.PF
※※
-OMU0007-B
Flow specification when [Ft] is selected by the units selection function
Model
PFG3#0
Applicable
SMC Flow
Switch
Model
PFMB7201
PFMB7501
PFMC7501
PFMB7102
PFMC7102
PFMB7202
PFMC7202
PF3A703H PF3A706H PF3A712H
Rated flow range
0.08 to
7.06 cfm
0.2 to
17.7 cfm
0.4 to
35.3 cfm
0.8 to
70.6 cfm
1.1 to
105.9 cfm
2.2 to
211.9 cfm
4.5 to
423.8 cfm
Flow
Set flow rate
range
Instantaneous
flow
-0.36 to
7.42 cfm
-0.9 to
18.6 cfm
-1.8 to
37.1 cfm
-3.6 to
74.2 cfm
-5.3 to
111.2 cfm
-10.6 to
222.6 cfm
-21.5 to
445.0 cfm
Accumulated
flow
0 to
99,999,999,
999.9 ft
3
0 to 999,999,999,999 ft
3
0 to 999,999,999,990 ft
3
Minimum
setting unit
Instantaneous
flow
0.01 cfm
0.1 cfm
0.2 cfm
0.5 cfm
Accumulated
flow
0.1 ft
3
1 ft
3
10 ft
3
Accumulated volume per
pulse
0.1 ft
3
/pulse
1 ft
3
/pulse
10 ft
3
/pulse
Display
Displayable
range
Instantaneous
flow
-0.36 to
7.42 cfm
-0.9 to
18.6 cfm
-1.8 to
37.1 cfm
-3.6 to
74.2 cfm
-5.3 to
111.2 cfm
-10.6 to
222.6 cfm
-21.5 to
445.0 cfm
Accumulated
flow
0 to
99,999,999,
999.9 ft
3
0 to 999,999,999,999 ft
3
0 to 999,999,999,990 ft
3
Minimum
display unit
Instantaneous
flow
0.01 cfm
0.1 cfm
0.2 cfm
0.5 cfm
Accumulated
flow
0.1 ft
3
1 ft
3
10 ft
3