-15-
No.PF
※※
-OMU0007-B
Attaching the connector to the sensor wire
•Strip the sensor wire as shown.
•Do not cut the insulator.
•Insert the corresponding wire colour shown in the table into the
pin number printed on the sensor connector, to the bottom.
Pin no.
Wire colour
Description
1
Brown
DC(+)
2
NC
-
3
Blue
DC(-)
4
White
IN
: The wire colours shown are for the PFMB, PFMC, and PF3A7 series cables.
•Check that the above preparation has been performed correctly, then part A shown should be pressed in by
hand to make temporary connection.
•Part A should then be pressed in using a suitable tool, such as pliers.
•The sensor connector cannot be re-used once it has been fully crimped.
In cases of connection failure such as incorrect order of wires or incomplete insertion, please use a new
connector.