-86-
No.PF
※※
-OMY0005
●
Product individual parameters (continued)
Index
Sub
index
Access
1
Parameter
Data
type
2
Initial
value
Data
storage
3
Set value
4
Remarks
dec
hex
1490 0x05D2
0
R/W
OUT
2
se
tt
in
g
(
A
C
)
AC_2ot
(Selection of output
type)
U8
0
Y
0: 1_P (Normal output)
1: 1_n (Reverse output)
1500 0x05DC
0
R/W
P2(n2)_L
(Selection of output
set value)
U32
0
Y
0 to 999,999,999
Common for all ranges, units, and
criterion
1510 0x05E6
0
R/W
P2(n2)_ft3
(Selection of output
set value)
U32
0
Y
0 to 99,999,999
Common for all ranges, units, and
criterion
1520 0x05F0
0
R/W
OUT
2
se
tt
in
g
(
P
L
S
)
PLS2_L
U8
0
Y
0: 10 (L/pulse)
1: 100 (L/pulse)
OUT2 accumulated pulse converted
value setting
1530 0x05FA
0
R/W
PLS2_Ft
3
U8
0
Y
1000 L range
0
:
0.1 (L/pulse)
1: 1 (L/pulse)
2000 L range
0: 1 (Ft
3
/pulse)
1: 10 (Ft
3
/pulse)
1540 0x0604
0
R/W
OUT
2
se
tt
in
g
(
P
L
S
/E
rr
)
2ot
(Selection of output
type)
U8
0
Y
0: 2_P (Normal output)
1: 2_n (Reverse output)
Setting of OUT2 normal and
reversed output
1600 0x0640
0
R/W
Dir
(Setting of the accumulated
flow direction)
U8
0
Y
0: Add
1: dEC1
2: dEC2
Addition/Subtraction
1800 0x0708
1
R/W
FiL_FLoW
(Digital filter_flow rate)
U8
0
Y
0: 1.0 sec
1: 2.0 sec
2: 5.0 sec
Set digital filter
2
R/W
FiL_PrES
(Digital filter_pressure)
U16
10
Y
0 to 3000 ms
10 ms increments (0 to 30 sec.)
1810 0x0712
0
R/W
FSC_PrES
(Fine adjustment of the
pressure span)
S16
0
N
-50 to 50
0.1% increments (-5 to 5
%
)
2000 0x07D0
0
R/W
Sub
(Sub screen display)
U8
0
Y
Refer to the Fig. Data for
the sub screen display
(Page
2020 0x07E4
0
R/W
rEv
(Reserved display)
U8
0
Y
0:
Normal display
1:
Reversed display
2030 0x07EE
1
R/W
Zero Cut(Flow)
U8
1
Y
0 to 10
Zero cut-off setting 1.0% increments
2
R/W
Zero Cut (PrES)
U8
0
Y
2050 0x0802
1
R/W
Mes disp/hide_PrES
(Measurement display/
hide_pressure)
U8
0
Y
0: diSP (displayed)
1: HidE (hidden)
Measurement display/hide setting
2
R/W
Mes disp/hide_tEMP
(Measurement display/
hide_temperature)
U8
0
Y
0: diSP (displayed)
1: HidE (hidden)
3
R/W
Mes disp/hide_AC
(Measurement display/
hide_accumulated flow rate)
U8
0
Y
0: diSP (displayed)
1: HidE (hidden)
2200 0x0898
0
R/W
SAvE
(Accumulated flow value
hold setting)
U8
0
Y
0: oFF (Not held)
1: 2.0min
2: 5.0min
2400 0x0960
0
R/W
Display OFF
(Display OFF setting)
U8
0
Y
0: on
1: oFF
2410 0x096A
1
R/W
S
e
cu
ri
ty
c
o
d
e
Pin
(Security code
Used/Not used)
U8
0
Y
0: unused
1: use
2
R/W
PinCode
(Security code
setting)
U16
0
Y
Setting range
0x0000 to 0x03E7
(0 to 999)