-84-
No.PF
※※
-OMY0005
●
Product individual parameters (continued)
Index
Sub
index
Access
1
Parameter
Data
type
2
Initial
value
Data
storage
3
Set value
4
Remarks
dec
hex
1290 0x050A
0
R/W
OUT
1
se
tt
in
g
(
A
C
)
AC_1ot
(Selection of output
type)
U8
0
Y
0: 1_P (Normal output)
1: 1_n (Reverse output)
1300 0x0514
0
R/W
P1(n1)_L
(Selection of output
set value)
U32
0
Y
0 to 999,999,999
Common for all ranges, units, and
criterion
1310 0x051E
0
R/W
P1(n1)_ft3
(Selection of output
set value)
U32
0
Y
0 to 999,999,999
Common for all ranges, units, and
criterion
1320 0x0528
0
R/W
OUT
1
se
tt
in
g
(
P
L
S
)
PLS1_L
U8
0
Y
0: 10 (L/pulse)
1: 100 (L/pulse)
OUT1 accumulated pulse converted
value setting
1330 0x0532
0
R/W
PLS1_Ft
3
U8
0
Y
1000 L range
0: 0.1 (L/pulse)
1: 1(L/pulse)
2000 L range
0: 1 (Ft
3
/pulse)
1: 10 (Ft
3
/pulse)
1340 0x053C
0
R/W
OUT
1
se
tt
in
g
(
P
L
S
/E
rr
)
1ot
(Selection of output
type)
U8
0
Y
0: 1_P (Normal output)
1: 1_n (Reverse output)
Setting of OUT1 output normal and
reserved output.
1400 0x0578
0
R/W
OUT
2
se
tt
in
g
OUT2
(Select the target for
setting)
U8
0
Y
0: FLoW (Flow rate)
1: Temp (Temperature)
2: PrES (Pressure)
3: AC (Accumulated)
4: PLS
(Accumulated pulse)
5: Err (Error output)
6: oFF (Output OFF)
1410 0x0582
1
R/W
OUT
2
se
tt
in
g
(
F
loW
)
ModE2
(Selection of output
mode)
U8
0
Y
0: HYS (Hysteresis)
1: Wind
(Window comparator)
2
R/W
2ot
(Selection of output
type)
U8
0
Y
0: 1_P (Normal output)
1: 1_n (Reverse output)
Setting of OUT2 output normal and
reserved output
1420 0x058C
1
R/W
P_2 (n_2)
(Selection of output
set value)
S16 2000
Y
Setting range
0x0028 to 0x1068
(40 to 4200)
Setting of OUT2 output set value
(Hysteresis)
2
R/W
H_2
(Setting of OUT1
hysteresis)
U16
200
Y
Setting range
0x0000 to 0x1040
(0 to 4160)
Setting of OUT2 hysteresis
(Hysteresis)
3
R/W
P2L (n2L)
(Lower limit of window
comparator)
S16 1200
Y
Setting range
0x0028 to 0x1068
(40 to 4200)
Setting of OUT2 output set value
(Lower limit of window comparator)
4
R/W
P2H (n2H)
(Upper limit of window
comparator)
S16 2400
Y
Setting range
0x0028 to 0x1068
(40 to 4200)
Setting of OUT2 output set value
(Upper limit of window comparator)
5
R/W
WH2
(Window comparator
hysteresis)
U16
400
Y
Setting range
0x0000 to 0x0820
(0 to 2080)
Setting of OUT2 hysteresis
(Window comparator)
6
R/W
dtH2
(Delay time ON)
U16
0
Y
Setting range
0x0000 to 0x1770
(0 to 6000)
Setting of OUT2 delay time ON
10 ms increments
7
R/W
dtL2
(Delay time OFF)
U16
0
Y
Setting of OUT2 delay time OFF