[F 0] Reference condition/Units selection function/Switch output function/Output object/
Display colour
Reference condition
Standard condition or normal condition can be selected.
Standard condition and normal condition are defined as follows:
•Standard condition: Displayed flow rate which is converted to volume at 20°C, 101.3 kPa (absolute pressure).
•Normal condition: Displayed flow rate which is converted to volume at 0°C, 101.3 kPa (absolute pressure).
Units selection function
This setting is only available for models with the units selection function.
: kPa/MPa can be selected if the product does not have the unit selection function.
Switch output type
The switch output function can be selected (NPN or PNP output).
Output object
Output object can be selected using OUT1 or OUT2.
Display colour
Select the colour of the main display.