-49-
No.PF
※※
-OMZ0002
Input of set values
b, When window comparator output mode is selected.
The sub screen (right side) displays the set value.
Change it with the UP and DOWN buttons.
(When reversed output is selected, the sub screen (left side) displays [n2L].)
Press the SET button to set.
Move to the input of the [P2H] set value.
The sub screen (right side) displays the hysteresis value.
Change it with the UP and DOWN buttons.
(When reversed output is selected, the sub screen (left side) displays [n2H].)
Press the SET button to set.
Move on to the setting of hysteresis.
Hysteresis setting
The sub screen (right side) displays the hysteresis value.
Change it with the UP and DOWN buttons.
Press the SET button to set.
Move on to delay time setting.
Delay time setting
The sub screen (right side) displays the delay time value.
Change it with the UP and DOWN buttons.
Press the SET button to set the OFF delay time [dtL2] after setting the ON delay
time [dtH2].
Press the SET button to set.
Move on to display colour setting. (page