-10-
No.PF
※※
-OMZ0002
∗
Adjustment and Operation
•
Connect load before turning on the power.
•
Do not short-circuit the load.
Although an error is displayed when the product load is short circuited, excess current may cause damage to the
product.
•
Do not press the setting buttons with a sharp pointed object.
This may damage the setting buttons.
•
Supply the power when there is no flow.
•
If using the product to detect very small flow rates, warm up the product for 10 to 15 minutes first.
There will be a drift on the display or the analogue output of approximate
±
2 to 3% immediately after the power
supply is turn on, within 10 minutes.
•
The output is off for 3 seconds after power is supplied.
•
Use settings suitable for the operating conditions.
Incorrect settings can cause operational failure.
•
During the initial setting and any subsequent flow rate setting, the product will switch the output
according to the existing settings until the changes are complete.
Confirm the output has no adverse effect on machinery and equipment before setting.
Stop the control system before setting if necessary.
•
Do not touch the LCD display during operation.
The display can vary due to static electricity.
∗
Maintenance
•
Perform regular maintenance and inspections.
There is a risk of unexpected malfunction of components due to the malfunction of equipment and machinery.
•
Turn off the power supply, stop the supplied air, exhaust the residual pressure and verify the release of
air before performing maintenance.
There is a risk of unexpected malfunction.
•
Perform drainage regularly.
If condensate enters the outside, it can cause failure of other pneumatic equipment.
•
Do not use solvents such as benzene, thinner etc. to clean the product.
They could damage the surface of the body and erase the markings on the body.
Use a soft cloth to remove stains.
For heavy stains, use a cloth lightly dampened with diluted neutral detergent, then wipe up any residue with a dry
cloth.
Содержание PF2MC7 Series
Страница 1: ...No PF OMZ0002 PRODUCT NAME Digital Flow Switch compatible MODEL Series Product Number PF2MC7 ...
Страница 56: ... 55 No PF OMZ0002 Bottom value display Peak value display ...
Страница 98: ... 97 No PF OMZ0002 Pressure loss PF2MC7501 500 L min PF2MC7102 1000 L min PF2MC7202 2000 L min ...
Страница 101: ... 100 No PF OMZ0002 Lead wire with M8 connector ZS 40 A M12 M8 conversion lead wire ZS 40 M12M8 A ...