-40-
No.PF
※※
-OMO0008-C
Made to Order
●
Model Indication and How to Order
Refer to page
for details of model indication and how to order.
●
Internal circuit and wiring example
When the lead wire with connector designated for PF2A7 is used, the wire colours will apply as shown on the
circuit diagram.
NPN (1 output) + Analogue (1 to 5 V) type
PF2A7
-
-28
-
-X560
PNP (1 output) + Analogue (1 to 5 V) type
PF2A7
-
-68
-
-X560
NPN (1 output) + Analogue (4 to 20 mA) type
PF2A7
-
-29
-
-X560
PNP (1 output) + Analogue (4 to 20 mA) type
PF2A7
-
-69
-
-X560
Max. 30 V, 80 mA
Internal voltage drop: 1 V or less
28: Analogue output: 1 to 5 V
Output impedance: 1 k
Ω
29: Analogue output: 4 to 20 mA
Load impedance
Power supply voltage 12 V: 300
Ω
Power supply voltage 24 V: 600
Ω
Max. 80 mA
Internal voltage drop: 1.5 V or less
68: Analogue output: 1 to 5 V
Output impedance: 1 k
Ω
69: Analogue output: 4 to 20 mA
Load impedance
Power supply voltage 12 V: 300
Ω
Power supply voltage 24 V: 600
Ω