background image

Technical

Information

Network Switch for Vnet/IP

TI 30A10A30-01E

TI 30A10A30-01E

©Copyright Sep. 2011 (YK)

5th Edition Dec. 2016 (YK)

Yokogawa Electric Corporation

2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 Japan

Tel.: 81-422-52-5634  Fax.: 81-422-52-9802

Summary of Contents for GRVSW-660FA

Page 1: ...Network Switch for Vnet IP TI 30A10A30 01E TI 30A10A30 01E Copyright Sep 2011 YK 5th Edition Dec 2016 YK Yokogawa Electric Corporation 2 9 32 Nakacho Musashino shi Tokyo 180 8750 Japan Tel 81 422 52 5...

Page 2: ...Blank Page...

Page 3: ...ing of the Vnet IP systems and contains the functions and speci cations of the Recommended Switches Read this document thoroughly before configuring the Vnet IP network and refer to the user s manual...

Page 4: ...tered trademark of YOKOGAWA Ethernet is a registered trademark of Xerox Corporation All other company and product names mentioned in this document are trademarks or registered trademarks of their resp...

Page 5: ...4 Family 2 4 2 2 1 Name of Each Part and Descriptions 2 4 2 2 2 Mounting 2 6 2 2 3 External Dimensions 2 6 2 3 MAR1040 Family 2 7 2 3 1 Name of Each Part and Descriptions 2 7 2 3 2 Mounting 2 11 2 3 3...

Page 6: ...store to default clear config factory 4 10 4 3 5 Save Backup configuration copy 4 10 4 3 6 Port Disable for unused port shutdown 4 11 4 3 7 Set management IP address network parms 4 11 4 3 8 Cascaded...

Page 7: ...Recommended Switch in case it is used for Vnet IP Use it only for Vnet IP as other network connection is not guaranteed or supported Categories of Recommended Switches Two types of the recommended Swi...

Page 8: ...ration models for BUS1 or BUS2 Recommended L2SW has an identical configuration model for BUS1 and BUS2 2 The default configuration is available only for the managed switches The Unmanaged Switch does...

Page 9: ...RU GRVSW 669FA MAR1040 4C4C4C4C9999EMMHRY1 AC AC GRVSW 670FA MAR1040 4C4C4C4C9999ELLHRY1 DC DC BUS2 GRVSW 671FA MAR1040 4C4C4C4C9999EM9HRY2 16 16 AC 40 to 70 19 Rack 1RU GRVSW 672FA MAR1040 4C4C4C4C99...

Page 10: ...ly Ports Power Supply Operating Temp C Mounting RJ 45 SFP P1 P2 L2SW BUS1 BUS2 GR2SW 699FA SPIDER II Giga 5T 2S EEC SPIDER II 5 2 DC 40 to 70 DIN Rail Note The SFP port is not for dual purpose Ports N...

Page 11: ...k When an Unmanaged Switch place on the edge of a network fails the failed part of the network can be inferred by using Network Status Display Dialog Box in HIS Do not place an Unmanaged Switch on a p...

Page 12: ...work is not applicable F010105 ai HIS HIS other switch 1 FCS HIS HIS Not Edge point GR2SW Unmanaged Switch Two connections to other switches ENG HIS ENG HIS ENG HIS other switch 1 Connecting to two or...

Page 13: ...an optical fiber connection 2 For Vnet IP connections single mode optical fiber cables are recommended When installing optical fiber cables for the first time use single mode optical fiber cables that...

Page 14: ...s regarded as a USB memory when connected to a computer ACA image is as shown below F010301 ai Figure ACA image For more information see section 3 1 4 Terminal Cable A terminal cable MS Code GRVCAB 67...

Page 15: ...e terminal pin functions are as shown below Table Terminal Pin Function RS40 Family Pin Function 1 P1 DC power input 2 FAULT output 3 P1 DC power input 4 P2 DC power input 5 FAULT output 6 P2 DC power...

Page 16: ...ch vender DIP switch This DIP switch de nes HIPER Ring operating priority Refrain from changing this DIP switch setting from the default The default setting is RM ON and Stand by ON USB interface An A...

Page 17: ...the figure below Attach the device s upper snap in guide into the DIN rail and press it down against the DIN rail until it snaps into place F020102 ai Figure Mounting on the DIN rail RS40 Family To ta...

Page 18: ...N60320 C14 standard The redundant power unit model GRVSW 664FA Vender model name MACH104 20TX FR has two inlet sockets for P1 and P2 AC power input An AC power cable is not included in the MACH104 fam...

Page 19: ...functional when using ring network technology supported by the network switch vender USB interface An ACA is connected with the Recommended Switch via USB interface V 24 interface V 24 interface conn...

Page 20: ...as instructed by the manufacturer and make sure the device is resting on both rails to protect the device from vibrating MACH104 family device of the Recommended Switch is designed without a fan howev...

Page 21: ...2 GRVSW 670FA Vender model name MAR1040 4C4C4C4C9999ELLHRY1 DC x 2 L3SW models for BUS2 GRVSW 671FA Vender model name MAR1040 4C4C4C4C9999EM9HRY2 AC x 1 GRVSW 672FA Vender model name MAR1040 4C4C4C4C...

Page 22: ...ock see section 2 4 2 AC power cable is not included in the MAR1040 family Please prepare AC power cable allowed to be used in the local regions For redundant power unit model use both P1 and P2 power...

Page 23: ...atus as delivered from the factory 3 These LEDs become functional when using ring network technology supported by the network switch vender USB interface An ACA is connected with the Recommended Switc...

Page 24: ...The SFP port is for dual purpose RJ45 SFP combo port The combo port will select SFP interface automatically when the SFP module is installed Port status LED Each port has 2 port status LEDs The LED on...

Page 25: ...device is resting on both rails to protect the device from vibrating MAR1040 family device of the Recommended Switch is designed without a fan however it requires suf cient ventilation Provide a fan f...

Page 26: ...Figure Name of Each Part SPIDER II Family Power input and ground A 3 pin plug in terminal block is installed to this connecter The list of the terminal pin functions is shown below Table Terminal Pin...

Page 27: ...Status Data Access RJ 45 port status LEDs The green and yellow LEDs at the individual port display port related information Table SFP port status LED function SPIDER II Family LED name Reaction Meani...

Page 28: ...nst the DIN rail until it snaps into place F020403 ai Figure Mounting on the DIN rail SPIDER II Family To take the SPIDER II family device off the DIN rail insert a screwdriver horizontally under the...

Page 29: ...V DC 100 to 240 V AC 47 to 63 Hz 100 to 240 V AC 50 to 60 Hz 24 to 48 V DC Operating voltage range 9 6 to 60 V DC 90 to 265 V AC 47 to 63 Hz 18 to 60 V DC 9 6 to 32 0 V DC Power consumption 20 W max 3...

Page 30: ...1 L2 L1 Sleeve with insulation cover Figure Cable assembly with sleeve Table Sleeve for Applicable Cables Cable Thickness Length of exposed wire mm Sleeve dimensions mm Weidmuller Model Number L1 L2 d...

Page 31: ...lat blade screw driver with tip thickness 0 6 mm axis radius 3 5 mm is recommended when connecting cables Loosen the pressure clamp of the terminal block by turning the screw counterclockwise Firmly i...

Page 32: ...e switch cfg le in the ACA from where the running con g and startup con g les are copied F030101 ai NVRAM Nonvolatile RAM startup config Duplicate running config System Memory RAM System Memory RAM sw...

Page 33: ...created in the ACA Save the switch cfg le to the computer for backup 3 3 Restore configuration from ACA The procedure to restore the con guration from an ACA is described as below 1 Clear the ACA devi...

Page 34: ...late VT 100 terminal with the computer The connection setup parameters for the terminal software are as shown below Speed 9600 bps Data 8 bit Parity None Stopbit 1 bit Handshake None Several of the co...

Page 35: ...lowing underlined characters in the login window User admin Password private F040102 ai Copyright c 2004 2010 Hirschmann Automation and Control GmbH All rights reserved MACH Release L2P 06 0 01 Build...

Page 36: ...a limited set of available commands in the Privileged Exec mode Privileged Exec Most of the basic operation commands are available in this mode VLAN Vlan All the commands pertaining to VLANs are grou...

Page 37: ...er function Command lines that are executed in the past can be stored into the history buffer of the device These command lines can be reused Entering Ctrl P go to previous line in history buffer Ente...

Page 38: ...onfig all commands are available in Privileged Exec mode For recording the configuration script as a text file use the log function of the terminal software A sample display of show running con g comm...

Page 39: ...re Release 05 1 00 Boot Software Build Date 2009 10 16 19 43 OS Software Release L2P 06 0 01 OS Software Build Date 2010 09 24 21 19 Backplane Hardware Revision 1 02 15 0102 Backplane Hardware Descrip...

Page 40: ...ACA is not present Not in sync The current configuration is not synchronized with ACA Or no valid configuration file exists in ACA Wrong machine The configuration file in ACA is not available Or the f...

Page 41: ...10 Disable Auto Down Enable Disable Enable Ignore 0 1 11 Disable Auto Down Enable Disable Enable Ignore 0 1 12 Disable Auto Down Enable Disable Enable Ignore 0 1 13 Disable Auto Down Enable Disable En...

Page 42: ...the link is up or down Up The link is up Down The link is down Cable Cross PhysMode Fix The con guration of straight crossover MDI MDI X manual selection for RJ 45 port of which auto negotiation is d...

Page 43: ...ion 4 3 5 Save Backup configuration copy For Recommended Switch several types of con guration les such as running con g and startup con g exist See section 3 for more information regarding the con gur...

Page 44: ...utdown command display To confirm the port status see section 4 3 3 4 3 7 Set management IP address network parms To assign a management IP address for the Recommended Switch use network parms command...

Page 45: ...the cascaded point of L3SWs where each L3SW has the same IP address 192 168 3 253 by default Therefore the IP address assigned to either L3SW 1 or L3SW 2 of Port 3 must be changed to a unique address...

Page 46: ...in Privileged Exec mode A sample display of show ip interface brief command execution is as shown below By using this command con rm if the modi cation of assigned IP address for each port is correct...

Page 47: ...Admin Physical Physical Link Link Cable Cross Flow Device VLAN Intf Type Mode Mode Status Status Trap PhysMode Fix Mode status Prio 1 1 Enable Auto Down Enable Disable Enable Ignore 0 1 2 Disable Aut...

Page 48: ...e of a network with added domain 2 BUS1 side only To reactivate the disabled L3SW port use no shutdown command See section 4 3 6 The following example shows the command to activate the port 2 of the L...

Page 49: ...overy delay set to 200ms Hirschmann MACH Config mrp current domain advanced mode enable Advanced Mode react on link change set to Enabled Hirschmann MACH Config mrp current domain operation enable Ope...

Page 50: ...and shall be used for confirming the setting status of the FAULT terminal action An example is as shown below after the show signal contact command is executed F040319 ai Hirschmann MACH show signal c...

Page 51: ...r RIP Enable Simple mode RIP update timer 1 second RIP send version RIP2 RIP1 compatible mode RIP receive version Both RIP1 and RIP2 Multi cast routing Enable IGMP Enable Multi cast routing protocol P...

Page 52: ...em Description Hirschmann Railswitch System Version L2P 06 0 01 Build 2010 09 24 18 18 vlan database exit network protocol none network protocol hidiscovery off RMA operation RMA entry configure inter...

Page 53: ...gement Hirschmann Signal Contacts signal contact 1 mode auto Hirschmann SNMP Access Control SNTP Hirschmann Broadcast Limiter Hirschmann Temperature Limit Settings users passwd admin v1 81449548fb49a9...

Page 54: ...RMA entry configure interface 1 1 exit interface 1 2 exit Snip interface 1 3 to 1 23 repeating the same setting interface 1 24 exit Address Conflict Detection Bridge Address Learning Maximum size of...

Page 55: ...ter Hirschmann Temperature Limit Settings users passwd admin v1 81449548fb49a99b7cba5001ed1bea8a4988eed61485abb02cde3593112d011c users snmpv3 authentication admin md5 users snmpv3 encryption admin des...

Page 56: ...idiscovery off RMA operation RMA entry configure interface 1 1 exit interface 1 2 exit Snip interface 1 3 to 1 15 repeating the same setting interface 1 16 exit Address Conflict Detection Bridge Addre...

Page 57: ...SNMP Access Control SNTP Hirschmann Broadcast Limiter Hirschmann Temperature Limit Settings users passwd admin v1 81449548fb49a99b25293d03eb0e98afa6b1c9250663311083029e54190569fd users snmpv3 authenti...

Page 58: ...g active Parameter string escape handling 1 Characters to be preceded with escape char System Description Hirschmann MACH System Version L3P 06 0 03 Build 2011 03 23 20 34 vlan database exit network p...

Page 59: ...mains exist No entries in alarm table MAC IP Based Port Security ProfinetIO Hirschmann Precision Time Protocol PTP IEEE 1588 Hirschmann Ring Coupling Note master slave also for single part of configur...

Page 60: ...9 ai no spanning tree Tracking IGMP Snooping set igmp set igmp query ports to filter enable ip igmp no ip igmp software dscp value ip pimdm ip multicast router ospf exit router rip enable update timer...

Page 61: ...regated before executing this procedure unless otherwise the Vnet IP network will become unstable caused by the address con ict during an incomplete con guration Clear Interface configuration pre assi...

Page 62: ...erface 9 3 created Hirschmann MACH Vlan vlan routing 14 Logical interface 9 4 created Figure Create VLANs The Logical interface number shown above indicates the virtual router port for each VLAN To co...

Page 63: ...t s con guration by using show running con g command To confirm the VLAN ID assigned for each port use show vlan port all command The following example shows the result of show vlan port all command e...

Page 64: ...ration for VLAN Similarly con guration parameters to all virtual router ports for every VLAN are set After virtual router port configuration setting confirm each virtual router port configuration by u...

Page 65: ...routing configuration 1 4 F0A0208 ai Hirschmann MACH show running config Current Configuration Parameter string escape handling 1 Characters to be preceded with escape char System Description Hirschma...

Page 66: ...interface 1 6 to 1 8 repeating the same setting interface 1 9 set igmp forward all vlan pvid 13 vlan participation exclude 1 vlan participation include 13 exit Snip interface 1 10 to 1 12 repeating th...

Page 67: ...E 802 3af Selftest Hirschmann HIPER Ring Fast HIPER Ring No Fast HIPER Ring ID exist Sub Ring No Sub Ring ID exist LLDP IEEE802 1AB Link Layer Discovery Protocol Media Redundancy Protocol IEC 62439 Ed...

Page 68: ...c20051a users passwd user v1 81439e52f35ecc4b248bb9be2bd8825f0e3067dc4aa498f7670ad5dc2cc07445 users snmpv3 authentication user md5 users snmpv3 encryption user des v1 81439e52f35ecc842032502ec1b91b287...

Page 69: ...cable cannot be reused unless the interface speed is downgraded However the following restrictions are caused by downgrading the speed to 100 Mbps Restrictions Open communication on Vnet IP is not ava...

Page 70: ...The total loss must not exceed 5 dB 2 Quality of signal transmission affected by the modal bandwidth Perform continuous PING test with 1 500 byte packet length between a pair of L2SW connected to the...

Page 71: ...ng the number of cascaded layer 2 switches This relationship is shown in the following table However the long haul connection exceeding 40 km degrades the time synchronization accuracy of the network...

Page 72: ...Blank Page...

Page 73: ...riptions on SPIDER II Unmanaged Switch are added 1 1 3 Ditto 2 4 Ditto All pages Typographical and grammatical errors are corrected Feb 2016 4th Edition 1 2 Revised SFP module 2 5 Revised Hardware Spe...

Page 74: ...Written by Yokogawa Electric Corporation Published by Yokogawa Electric Corporation 2 9 32 Nakacho Musashino shi Tokyo 180 8750 JAPAN Subject to change without notice...

Reviews: