Problem
Possible cause
Solution
Insufficient rotating
angle
MSUA series has an angle
adjustment mechanism.
The adjustment bolt for angle
adjustment is set at a smaller
angle than required.
Set the adjustment bolt correctly.
Excessive loosening of the adjustment bolt will
remove the stop side of the stopper lever from
the adjustment bolt.
Adjust it within the adjusting range.
The auto switch does
not operate or
operates incorrectly.
Effect of an external magnetic
field.
Check that there is no strong magnetic field
present.
Trouble with the electrical
circuit
Check that there is no trouble with the electrical
circuit.
Trouble with the electrical
specification
Check there is no trouble with the electrical
specification.
Precautions for the troubleshooting table
1. Causes of the operation failure due to product life are not shown in the troubleshooting table.
2. For failures due to causes other than -those shown in the troubleshooting table and product life,
please contact SMC, as a disassembly investigation of the product may be required.
- 44 -
2020-10-13 11:15
DI987004