MDSUA1/3 auto switch mounting
External view and descriptions of auto switch unit
Solid state auto switch
<Applicable auto switches>
3-wire type: D-S99(V), D-S9P(V)
2-wire type: D-T99(V)
Reed auto switch
<Applicable auto switches>
D-97, D-93A (with indicator light)
D-90, D-90A (without indicator light)
1. Removal of the switch block
Remove the cross recessed round head screw (1)
and remove the switch block.
1. Preparation
Loosen the cross recessed
round head screw (2). (2 to 3
rotations)
* The screw is tentatively fixed
for shipment.
2. Mounting of the solid state switch
Hold the solid state
switch with the cross
recessed round head
screw (1) and the
holding block (A).
* Appropriate
tightening torque:
0.4 to 0.6 (N
・
m)
2. Mounting of the Reed switch
Insert the Reed switch into the
switch block port until it touches the
end.
* D-97 and D-93A type switches
need to be inserted in the direction
shown in the right Fig.
* D-90 and D-90A are round
shaped switches. Mounting
direction is not specified for them.
* Holding block (A) moves along the groove. Move it
to the mounting position before mounting the switch.
- Adjust the switch sensoring position by the cross
recessed round head screw (1) before operating the
product.
3. Holding the Reed switch
Tighten the cross recessed round
head screw (2) to fix the Reed
switch in place.
Appropriate tightening torque:
0.4 to 0.6 (N
・
m)
Adjust the switch sensoring position by the cross
recessed round head screw (1) before operating the
product.
- 39 -
2020-10-13 11:15
DI987004