Note
〉
None that the product whose inside of the rotary unit and table unit can not be guaranteed.
Periodic inspection
Periodic inspection is necessary for optimum use.
(1) Inspection point
①
Loosening of an adjusting bolt fixed by a nut
②
Loosening of a hexagon socket head cap screw fixing a body
③
Loosening of a mounting base of an actuator
④
Checking rotating operation
⑤
Checking rotation angle and rotating position
⑥
External and internal leak
⑦
Checking ON and OFF operation od f switch
Check the above points and if a failure is found, retighten screws, replace parts or repair the product.
(2) Inspection interval
In order to use the high precision rotary table/series MSUA in optimum condition, please inspect it once or
twice a year.
- 42 -
Model
Screw torque N
・
m
③
④
MSUA1
0.8~1.2
0.8~1.2
MSUA3
0.8~1.2
0.8~1.2
MSUA7
2~3.4
2~3.4
MSUA20
4~6
4~6
Table. 18