No.LFE****-OMZ0013
■[F80] Power saving mode
The display can be turned off to reduce power consumption. (Reduced by approx. 12%)
When this function is selected, if no buttons are pressed for 30 seconds, the display will enter power saving
mode.
In the default setting, power saving mode is OFF (display is ON).
<Operation>
Press the
or
button in function selection mode to display [F80] on the main screen.
The sub screen alternately displays [dSP] and the current set value.
Press the
button.
Sub screen
The display can be turned off to save
power.
Press the
or
button to select the power saving mode setting.
Press the
button to set. Return to function selection mode.
[F80] Setting of power saving mode complete.
In power saving mode, the decimal points on the main display will flash.
When any button is activated, the display will turn on. If no button operation is performed within 30 seconds,
the display will turn off again.