-31-
No.LFE****-OMZ0013
<Operation>
1. Selection of output mode
Press the
or
button in function selection mode to display [F 2] on the main screen.
The sub screen displays [oUt2] and the currently set output mode alternately.
*: If OUT2 is not provide, the display will be [---].
Press the
button.
Sub screen
Press the
or
button to select the desired output mode.
Press the
button to set. Move on to the setting of reversed output.
* Hysteresis/ comparator mode for fluid temperature are items which are not used for this product.
2. Setting of reversed output
Sub screen
Press the
or
button to select reversed output mode.
Press the
button to set. Move on to the input of set values (ON-OFF point).
*: When the accumulated pulse output is selected, the setting has been completed now.
Normal output
Reversed output