IN19856
- 42 -
Rev 2
TYPE Hex Bits 7 - 4
Mpa
0x0
0000
kg/cm 0x1
0001
BAR
0x2
0010
PSI
0x3
0011
Kpa
0x4
0100
Counts 0x5
0101
Figure 31 - Config engineering unit types
23.3.
Initial Configuration Parameters
Item
Value
IP address
192.168.1.20
Subnet
255:255:255:0
DHCP
Off
Enable POE
Off
Enable Hold
Off
Byte Swap
Off
Pressure Unit
Counts
Engineering Unit
Counts
User Gain
8
User Sensitivity
2
Webpage ID
user
Webpage Password user
Figure 32 - ITV Initial Configuration
Appendix
24.
Explicit Message Example using
LabVIEW™ software
It is possible to control the ITV with a
LabVIEW™ software
program.
The following is a simple example of a
LabVIEW™ software
block diagram. The program can send a
pressure or vacuum setpoint value to the ITV and will read the ITV pressure and status.
Figure 33 - Sample LabVIEW™ software Block Diagram