IDX-OM-W022
Air Dryer
12 Specification for Option S
12-1 Safety instructions
12- 1
IDU Series
12 Specification for Option S
12-1 Safety
instructions
When handling the product, take care to the following precautions.
Warning
Only qualified persons are allowed to wire the product.
- Before wiring, be sure to shut off the power supply. Never perform wiring work while the
product is energized.
- Ensure a stable power supply with no voltage surges.
- Use a power supply suitable for the specifications of the product.
- Be sure to connect the ground connection.
- Grounding should never be connected to a water line, gas line or lightning rod.
- Multiple wiring is dangerous because it may lead to heat generation and cause a fire.
- Do not modify the electrical wiring of the power supply.
12-2 Specifications
The option allows the connection of a power cable to a terminal block.
IDU*-20/23 is equipped as standard.
12-3 Electric
circuit
For details of the electric circuit, refer to the label on the back of the front panel of this product (see page 1-1).
For IDU8E/11E/15E1-10
Rear panel
You can see the terminal block when you
remove this cover. Connect the power
cable through the membrane grommet.
Terminal connecting screw: M3
Crimped terminal width: 6.5mm or less
Applicable electric wire: 1.25mm
2
or more
L N PE
( )
To the user’s machine
Rubber grommet
Power supply cable entry