IDX-OM-W022
Air Dryer
2 Transportation / Installation
2-3 Cautions about Reinstallation
2
-
6
IDU Series
2-3 Cautions about Reinstallation
Caution
No one but someone who has enough knowledge about the product and incidental
devices should reinstall in another place. And following instructions must be executed.
If you move the product and reinstall it into another place after some operations (including trial running), instructions
that are not only following ones but also all of those in the chapter 2 should be followed.
Disassembly of the power cable
Cut off the power source when you disassemble the power cable.
Warning
No one but qualified personnel should do the electric wiring.
Cut off the power supply for safety before the wiring. Do not work under energized
condition.
Disassembly of the air piping
Warning
No one but qualified personnel should do the air piping.
Separate the compressor from the product for safety before removing the iping. Do not
remove any piping when there is remaining compressed air pressure inside of it.
Remove the s
eal tape completely after detaching the piping. Remained tape will cau
se imperfect cooling
and failure by entering into the body of the product.
Residual compressed air pressure release procedure
•
Even while the dryer is removed, only when compressed air is needed, open the bypass piping valve.
•
Close the compressed air inlet and outlet valve.
•
Make sure the ball valve located next to the auto drain opened.
•
Open the auto drain residual pressure release valve to release air pressure inside the product. Refer to
the
figure at right.
Bowl Assembly
The remainder depressure cock.
∗
It opens when turning in the direction of the
arrow of figure.