IDX-OM-W022
Air Dryer
8
Specification for Option K
8-1 Safety instructions
8- 1
IDU Series
8
Specification for Option K
8-1 Safety
instructions
When handling the product, take care to the following precautions.
Warning
- Do not remove the auto drain with the air pressure remaining internally. If the compressed
air is left in the product, when some part is loosened, it may cause sudden lurching or
other unexpected accidents.
- When removing the panel, wear protective gloves to prevent injuries.
- There is a risk of touching drained waste liquid during replacement.
When draining, follow the user’s own procedure to keep operators safe. (E.g. Wear
protective goggles, apron and gloves to prevent contact with the drained condensate.)
- When oils can enter the drained condensate, waste water treatment is necessary. Follow the
bylaws or rules of the local municipality for disposal.
8-2 Specifications
The maximum operating pressure 1.6MPa. A metal bowl with a level gauge which can confirm the water
label is used for auto drain.
Model
Item
IDU8E/11E/15E1-*-K
Auto drain type
Float type
Auto drain valve type
N. O.
(
Normal Open: Open under non-energized status.
)
Operating pressure
0.15 to 1.6MPa
KQ2H10-02AS
φ
10
Fluid level indicator
Drain Port
Case thermal insulator
AD48-8-A-X2112
bowl assembly
One-touch Fittings