IDX-OM-U010
Chapter 10 Specification for Option R
IDFC60/70/80/90 Series
10.1 Safety instructions
10-1
Chapter 10
Specification for Option R
Option R installs a Ground Fault Circuit Interrupter (GFCI), it will shut off the power supply in case the
product should have over current or current leakage. For the details of the GFCI such as the
specifications and mounting position, see 10-2 and 10-3.
10.1 Safety instructions
When handling the product, take care to the following precautions.
10.2 Specifications of GFCI
Model
Item
IDFC60-20-R
IDFC70-20-R
IDFC80-20-R
IDFC90-20-R
Current rating (A)
10
15
20
30
Sensitivity current (mA)
30
Only qualified person must perform wiring and observing the following points.
- Be sure to shut off the power supply before wiring. For safety, do not perform any work on the unit
with the power supply on. The power supply cannot be completely shut off just by turning off the
Switch with lamp. Be sure to turn off all power lines connected to the product.
- Supply the power from a stable source, free from surges.
- Provide the power suitable for the product specifications.
- Be sure to ground the product for safety. Without grounding, the GFCI cannot operate normally.
- Do not ground to water pipe, gas tube or lightening rod line.
- Do not connect too many wires to the same outlet, which could results in heat generation and fire.
- Do not retrofit the wiring of the dryer and the power supply line.
WARNING