Chapter 3 Transportation/Installation
IDFC60/70/80/90 Series
3.3
Cautions for Reinstallation
3-7
3.3 Cautions for Reinstallation
If the product is moved and reinstalled in another place after some trial operations, the following
instructions must be followed as well as procedures in Chapter 3.
Removing the power cable
Disconnect the power source before removing the power cable.
Disconnecting air pipes
Remove the seal tape completely after removing the piping. Loose seal tape can clog up the system.
Releasing residual pressure
1) Open the bypass valve during air dryer removal, only when compressed air is required.
2) Close the compressed air inlet and outlet valve.
3) Ensure that the ball valve of the auto drain is opened.
4) Remove the drain cock holding clip.
5) Rotate the drain cock of the auto drain to "O" side, and exhaust the compressed pneumatic air from
the product.
Only properly trained, qualified personnel are allowed to perform reinstallation.
CAUTION
- Only properly trained, qualified personnel are allowed to perform wiring.
- Disconnect the power source before wiring. Do not work under energized
condition.
WARNING
Drain cock
“O”: Open
Remove the clip
- Only properly trained, qualified personnel are allowed to perform piping works.
- Separate the compressed air source from the product before disconnecting the air
pipe.
- Do not disconnect any piping when there is residual air pressure inside of the pipe.
WARNING