Communication Functions
Contact Input/Output Communication Specifications
Contact Input/Output Pin Nos.
Item
Specifications
Contact input signal 1, 2
Insulation method
Photocoupler
· Run/Stop signal
· External switch signal
Rated input voltage
24 VDC
Operating voltage range
21.6 to 26.4 VDC
Rated input current
5 mA TYP
Input impedance
4.7 k
Ω
Contact output signal 1, 2, 3
Rated load voltage
48 VAC or less/30 VDC or less
· Run status signal
· Alarm status signal
· Signal for completion of preparation
(TEMP READY), etc.
Maximum load current
500 mA AC/DC (Resistance load)
Minimum load current
5 VDC 10 mA
24 VDC Output voltage
24 VDC
±
10 % 500 mA MAX
∗
1
(No inductive load)
Pin no.
Application
Division Initial value (Default setting)
1
24 VDC output
Output
—
2
24 VDC output
Output
—
3
24 VDC output
Output
—
4
Contact input signal 1
Input
OFF
5
Common of contact output signal 1 Output
—
6
Common of contact output signal 2 Output
—
7
Common of contact output signal 3 Output
—
8
None
—
—
9
24 COM output
Output
—
10
24 COM output
Output
—
11
Common of contact input signal Output
—
12
Contact input signal 2
Input
OFF
13
Contact output signal 1
Output Run status signal (N.O. type)
14
Contact output signal 2
Output Remote status signal (N.O. type)
15
Contact output signal 3
Output
Alarm signal (N.C. type)
∗
1 When using the power supply of this product, make sure that the total load current is 500 mA or less.
D-sub 15-pin female (socket) type
Contact input/output signal connector
8
1
15
9
For details, refer to the “Operation Manual”
on the website, www.smc.eu
17
HRR
Series
Содержание HRR Series
Страница 30: ......