-38-
No.EX##-OMI0032-C
•
Wiring of the branch cable and connector for connecting load
(Connector for connecting load: Applicable only to EX510-S 01 )
•
Wiring of branch cables and load mounting connector are shown below.
•
Insert load mounting connector with pinsette. After insertion at all load mounting connectors is completed,
insert connector locking pin. The output no. of each load mounting connector can be found on the below.
∗
: For crimping of a branch connector, refer to page 17.
•
Load connecting connector pin assignment (EX510-S 01 )
•
EX510-S001
Function
No.
Name
CN0
CN1
CN2
CN3
CN4
CN5
CN6
CN7
4
COM
Load actuating common (+)
3 Output
(n) OUT0
OUT2
OUT4
OUT6
OUT8
OUT10 OUT12 OUT14
2 Output
(n+1)
OUT1
OUT3
OUT5
OUT7
OUT9
OUT11 OUT13 OUT15
1
COM
Load actuating common (+)
•
EX510-S101
Function
No.
Name
CN0
CN1
CN2
CN3
CN4
CN5
CN6
CN7
4 Output
(n) OUT0
OUT2
OUT4
OUT6
OUT8
OUT10 OUT12 OUT14
3
COM
Load actuating common (
−
)
2
COM
Load actuating common (
−
)
1 Output
(n+1)
OUT1
OUT3
OUT5
OUT7
OUT9
OUT11 OUT13 OUT15
Содержание EX510-DXB1
Страница 33: ...32 No EX OMI0032 C Dimensions GW unit EX510 GPR1...
Страница 37: ...36 No EX OMI0032 C Wiring Internal circuit and wiring EX510 S001 EX510 S101...
Страница 38: ...37 No EX OMI0032 C EX510 S002 EX510 S102...
Страница 50: ...49 No EX OMI0032 C Mounting and Installation Installation Mounted by screw EX510 DX 1 EX510 DX 2...