4-3 Flange application
See table 6 for L dimension of the body.
JIS hexagon socket head bolt is neatly placed in the
rotary actuator groove.
4-4 Piping and operating direction
Fig-7 shows piping ports of the rotary actuator.
Table-7 shows the port size.
Fixed orifi
ce is equipped in the rotary actuator port. Don’t enlarge the hole. Enlarged hole increases the
operation speed of the rotary actuator and the impact which lead to cause the breakage of the rotary
actuator.
The axis rotates clockwise when pressurized from A port. Perform followings before piping.
a)
Flush or clean the piping to eliminate metal swarf, cutting oil and dust before connecting piping.
b)
Mind so that the piping swarf and sealing material do not enter into the piping when screwing in
piping and fitting. When using the seal tape, leave 1.5
~
2 threads.
4-5 Operating air
Air supplied to the rotary actuator shall be
cleaned by the filter. CRQ2 series is lubrication free.
Sealant tape
Winding
Expose approx. 2 threads
direction
-23-
Fig.6
Table 6
Size
L
Bolt
10
13
M 4
15
16
M 4
20
22.5
M 6
30
24.5
M 8
40
28.5
M 8
Table 7
Port size
Size
Port size
10
M5
×
0.8
15
20
Rc 1/8
,
G 1/8
NPT 1/8
,
NPTF 1/8
30
40
Port A
Port B
Fig.7
Port location
Fig. 8 Wrapping of pipe tape