1. Perform the following maintenance periodically in order to prevent possible danger due to
unexpected auto switch malfunction.
1) Secure and tighten auto switch mounting screws.
If screws become loose or the mounting, position is dislocated, retighten them after readjusting the
mounting position.
2) Confirm that there is no damage to lead wires.
To prevent faulty insulation, replace auto switches or repair lead wires, etc., if damage is discovered.
3) Confirm the detection setting position.
・
Red light of 1-color display auto switch
Confirm that the set position stops at the center of the operating range (red display area).
・
Conform the green light and position of the 2-color display auto switch.
Conform that the set position stops at the center of the appropriate operating range (green display
area). If stopped with the red LED lit, the operation may become unstable due to effects of the
equipment environment or external disturbance. So, set the mounting position at the center of the
appropriate operating range again.
2. Do not use solvents such as benzene, thinner etc. to clean the product.
They could damage the surface of the body and erase the markings on the body. For heavy stains, use a
cloth lightly dampened with diluted neutral detergent, then wipe up any residue with a dry cloth.
Handling Precautions
1. The protective cover supplied with the product when D-A9
□
or D-A9
□
V is shipped from
the factory is intended to absorb the impact generated by handling and prevent the auto
switch holding screw from falling. Do not remove this cover until immediately before
installing the auto switch on the rotary table.
-16-
Caution
Caution
2020-10-13 10:36
DI987004
Содержание CRQ2 Series
Страница 27: ...Table for calculation of Inertia moment 25...