- 9 -
Lubrication
①
This product should be used without lubrication. Although it will operate even if it is lubricated, it
could lead to sticking or slipping.
Maintenance and Inspection
①
During a maintenance inspection, do not disassemble the equipment with electrical power
or an air supply applied.
②
After the product has been disassembled for inspection, make sure to perform the appropriate
functionality inspection.
The product specifications cannot be met unless a functionality inspection is performed.
①
For lubrication, use the designated grease for each specific product.
The use of a non-designated lubricant could damage the seals.
Attention of auto switch
Design / Selection
①
Confirm the specifications.
Read the specifications carefully and use this product appropriately. The product may be damaged
or malfunction if it is used outside the specification range for current load, voltage, temperature or
impact.
①
Take precautions when multiple actuators are used close together.
When multiple auto switch actuators are used close proximity, magnetic field interference may cause
the auto switches to malfunction. Maintain a minimum actuator separation of 40mm.
The auto switches may malfunction due to the interference from the magnetic fields.
Warning
Caution
Warning
Warning
Caution
2020-10-13 10:33
DI987004