5) Applications in which the difference between the inlet and outlet pressure exceeds
0.1MPa must be avoided. Or the element is broken.
6) For air blow applications, prevent airborne particles from the operating environment
entering into the compressed air stream, or foreign matter may adhere to the
workpiece during the air blow.
7) If the air equipment is mounted on the outlet of the product, particles will be
generated from the equipment and required cleanliness may not be obtained.
Instead, install the air equipment at the inlet.
8) Do not install the product in an environment subjected to vibration and impact. This
may lead to breakage or malfunction.
9) Do not use the product in an environment subjected to sea water, water or (water)
vapour. This may damage the bowl.
!
Warning
1) Grease is used on the internal sliding parts and seals. The grease may flow to the
outlet side. Please contact SMC if this is a problem. If this is not acceptable, contact
SMC.
2) Select the model so that the maximum discharge value (instantaneous) of the flow
rate will not exceed the rated air capacity.
3) N.O. type auto drain should be used under the following requirements to avoid
operating failure. Output of compressor: 0.75kW or more. Discharged flow rate: 100
L/min (ANR) or more. If multiple auto drains are used, confirm used compressor has
capacity over the result of multiplying the above capacity and the number of used
auto drains. { For example, in case of two auto drain, the compressor need the
capacity over 1.5kW [200 L/min (ANR)]. } Set pressure more than 0.1 MPa.
Selection
capacity over 1.5kW [200 L/min (ANR)]. } Set pressure more than 0.1 MPa.
4) N.C. type auto drain should be used under the following requirements to avoid
operating failure. Operating pressure for AD37-A is 0.15MPa or more.
!
Warning
1) Do not drop or apply impact during transportation or installation. It will cause
damage to the product or operation failure.
2) Do not install in areas of high humidity or high temperature. Operation outside of the
product specification range may cause damage to the product or operation failure,
or shorten the product life.
3) Connect the product ensuring the direction of "1"(IN) and "2"(OUT) for air direction
or an arrow. Incorrect connections may cause malfunction.
4) Install with adequate space for maintenance beneath the product. Refer to the
Dimensions section of each part for necessary space.
5) Install vertically so that outlet of drain would turned downward. Use with the outlet of
drain turned horizontal or upward causes malfunction.
!
Warning
1) Before piping, perform flushing or cleaning of the piping, etc. to remove any cutting
chips, cutting oil, solid foreign matter, etc. from the piping. Contamination of piping
may cause damage or malfunction.
2) When installing piping, avoid chips and sealing materials from piping screws
entering the inside of equipment. Or malfunction may occur. Also, if sealant tape is
used, leave 1.5 to 2 thread ridges exposed at the end of the threads.
Piping
Mounting
-5-