M
OUNTING
3-3
Mounting
A TigerSwitch 10/100 unit can be mounted in a standard 19-inch
equipment rack or on a desktop or shelf. Mounting instructions for each
type of site follow.
Installing Optional Modules: Before mounting the switch, be sure you
install any optional modules. If you have purchased optional slide-in
1000BASE-T, 100BASE-FX, or 1000BASE-X (GBIC) media expansion
modules, install these modules now, following the instructions "Installing
an Optional Module into the Switch" on page 3-4.
Rack Mounting
Before rack mounting the switch, pay particular attention to the following
factors:
◆
Temperature: Since the temperature within a rack assembly may be
higher than the ambient room temperature, check that the
rack-environment temperature is within the specified operating
temperature range. (See page C-2.)
◆
Mechanical Loading: Do not place any equipment on top of a
rack-mounted unit
◆
Circuit Overloading: Be sure that the supply circuit to the rack
assembly is not overloaded.
◆
Grounding: Rack-mounted equipment should be properly grounded.
Particular attention should be given to supply connections other than
direct connections to the mains.
Содержание 6724L3 1
Страница 2: ......
Страница 12: ...COMPLIANCES viii ...
Страница 16: ...TABLE OF CONTENTS x ...
Страница 28: ...ABOUT THE TIGERSWITCH 10 100 1 12 ...
Страница 38: ...NETWORK PLANNING 2 10 ...
Страница 68: ...SPECIFICATIONS C 6 ...
Страница 70: ...ORDERING INFORMATION D 2 ...
Страница 76: ...Glossary 6 ...
Страница 80: ...INDEX Index 4 ...
Страница 81: ......