3-1
C
HAPTER
3
I
NSTALLING
THE
S
WITCH
Selecting a Site
TigerSwitch 10/100 units can be mounted in a standard 19-inch
equipment rack or on a flat surface. Be sure to follow the guidelines below
when choosing a location.
◆
The site should:
•
be at the center of all the devices you want to link and near a
power outlet.
•
be able to maintain its temperature within 0° to 50° C
(32 to 122° F) and its humidity within 10% to 90%,
non-condensing
•
provide adequate space (approximately two inches) on all sides for
proper air flow
•
be accessible for installing, cabling and maintaining the devices
•
allow the status LEDs to be clearly visible
◆
Make sure twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical
interference, such as radios, transmitters, etc.
◆
Make sure that a separate grounded power outlet that provides 100 to
240 VAC, 50 to 60 Hz, is within 2.44 m (8 feet) of each device and is
powered from an independent circuit breaker. As with any equipment,
using a filter or surge suppressor is recommended.
Содержание 6724L3 1
Страница 2: ......
Страница 12: ...COMPLIANCES viii ...
Страница 16: ...TABLE OF CONTENTS x ...
Страница 28: ...ABOUT THE TIGERSWITCH 10 100 1 12 ...
Страница 38: ...NETWORK PLANNING 2 10 ...
Страница 68: ...SPECIFICATIONS C 6 ...
Страница 70: ...ORDERING INFORMATION D 2 ...
Страница 76: ...Glossary 6 ...
Страница 80: ...INDEX Index 4 ...
Страница 81: ......