3.5 Electrical Connection 

Caution 

  The  power  supply  should be  fitted  with  a  switch  or  circuit  breaker in 

close proximity to the equipment and within easy reach of the operator. 
It  shall  be  clearly  marked  as  the  disconnecting  device  for  the 
equipment. 

  Avoid mis-wiring,  as  this  can  cause  malfunction,  damage  and  fire  to 

the product. 

  Use  voltage  that  is  within 

–15%  to  +10%  of  the  rated  voltage. 

Application of incorrect voltage may cause malfunction or damage. 

  Use electrical circuits that do not generate chattering in their contacts. 

  Do not bend or pull cables repeatedly. 

  The power supply should be fitted with a suitable fuse, see Table 3. 

 

Voltage

 

Appropriate 

fuse 

(Amps) 

AC 

50/60Hz

 

100, 200, 12, 24, 

48, 110, 220, 240V 

1.5 

DC 

24, 12, 6, 48, 110V 

Table 3 

 

  When connecting C-R element parallel to switching element, leakage 

current flows through C-R element and the leakage voltage increases. 

 

Figure 2 

 
Ensure that the voltage leakage across the coil is as follows: 
With AC coil: 15% or less of rated voltage. 
With DC coil: 3% or less of rated voltage 
 

Danger 

 

Disconnect  power  supply  before  removing  or  making  electrical 
connections. 

 

Cable entry must be made using metal conduit or cable gland, see 

Figure 5

 and 

Figure 7

 

Ass

embly of terminals to cable

 

  Use cables with insulated wires, stranded, 1.04 to 2.63 mm

2

  Terminate wires using crimp terminals (part number V2-M4  

– made by 

J.S.T.MFG.CO.,LTD or equivalent) to suit M4 screws. 

  Use crimping tool to attach terminals (part number YNT-1614 

– made 

by J.S.T.MFG.CO.,LTD or equivalent). 

3 Installation - continued 

  After crimping, check the crimp by slightly pulling the insulated wire. 

  Internal earthing: Use at least 2.63 mm

2

 or large wire 

 

Ass

embly of external ground terminal to cable

 

  Use cables with insulated wires, stranded, 4 to 6.64 mm

2

  Terminate wires using crimp terminals (part number V5.5-S4  

– made 

by J.S.T.MFG.CO.,LTD or equivalent) to suit M4 screws. 

  Use crimping tool to attach terminals (part number YNT-1210S 

– made 

by J.S.T.MFG.CO.,LTD or equivalent). 

  After crimping, check the crimp by slightly pulling the insulated wire. 

 
Assembly of cable to valve 

  Ensure cables have correct crimp terminals to suit M4 screws. 

  Ensure the terminal box is locked in position. 

  Remove the four M4 x 10 screws and carefully remove terminal cover 

ensuring mating surfaces are not damaged. 

  Feed cable through cable entry and attach wires to valve using M4 x 6 

round head screws with M4 washers.

 

  Ensure wires are correctly connected to the corresponding terminals.

 

  Replace  terminal  cover,  ensuring mating surfaces  are  not  damaged, 

and torque tighten cover screws to 1.35 to 1.45  N•m. 

 
 

 

Figure 3 

 

 

Figure 4 

 
 

Metal conduit threaded type entry 

  Metal conduit should be heavy gauge steel with parallel M20 thread. 

  Ensure  a  minimum  engagement  of  five  full  threads  and  secure  with 

locknut.

 

  During  assembly,  prevent  excessive  force  being  applied  to  the 

solenoid valve, by using a spanner on the flats provided on the valve.

 

  In humid environment, coat the threads with a liquid gasket. 

 
 
 
 
 

3 Installation - continued 

 

Figure 5 

 

Be sure to protect the cable used for earth from twisting. 

 

Figure 6 

Flameproof enclosure cable gland (not supplied) type entry 

  The cable gland connector must have the following certification.  

 

ATEX 

II 2 G Ex db IIC Gb 

 

  Select cable gland connector applicable to flexible cable O/D and with 

a parallel M20 or ½ NPT thread. 

  Follow  instructions supplied  with cable gland  on  how  to  assemble to 

cable. 

  Ensure  a  minimum  engagement  of  five  full  threads  and  secure  with 

locknut.

 

  During  assembly,  prevent  excessive  force  being  applied  to  the 

solenoid valve, by using a spanner on the flats provided on the valve.

 

  In humid environment, coat the threads with a liquid gasket. .

 

  Use a cable and cable gland rated for at least +90°C for temperature 

class T5.  

 
 

 

Figure 7 

 

3 Installation - continued 

 

Figure 8 

 

3.6 Lubrication 

 Caution 

  SMC products have been lubricated for life at manufacture, and do not 

require lubrication in service. 

  If a lubricant is used in the system, refer to catalogue for details. 

 

4 Settings 

4.1 Manual Override 

Caution 

  Since connected equipment will operate when the manual override is 

activated, confirm that conditions are safe prior to activation. 

 

Non-locking push type (tool required) 

  Push down the manual override button with a small screwdriver, etc. 

until it stops ON. 

  Hold this position for the duration of the check (ON position). 

  The manual override will return when released to the OFF position. 

 

 

Figure 9 

 

Slotted locking push type (tool required) 

  Push  down  the  manual  override  button  with  a  small  flat  head 

screwdriver until it stops and turn 90° clockwise to lock (ON position). 

  Turn anti-clockwise to release to the OFF position. 

 

Figure 10 