Series LECSC
*
1 If the system comprises of both CC-Link Ver. 1.00 and Ver. 1.10 compliant cables, Ver. 1.00 specifications are applied to the overall cable length and the cable length between stations.
*
2 USB communication and RS422 communication cannot be performed at the same time.
Specifications
Series LECSS
Model
LECSS1-S5
LECSS1-S7
LECSS2-S5
LECSS2-S7
LECSS2-S8
Compatible motor capacity [W]
100
200
100
200
400
Compatible encoder
Absolute 18-bit encoder
(Resolution: 262144 p/rev)
Main
power
supply
Power voltage [V]
Single phase 100 to 120 VAC
(50/60 Hz)
Three phase 200 to 230 VAC (50/60 Hz)
Single phase 200 to 230 VAC (50/60 Hz)
Allowable voltage fluctuation [V]
Single phase 85 to 132 VAC
Three phase 170 to 253 VAC
Single phase 170 to 253 VAC
Rated current [A]
3.0
5.0
0.9
1.5
2.6
Control
power
supply
Control power supply voltage [V]
Single phase 100 to 120 VAC
(50/60 Hz)
Single phase 200 to 230 VAC
(50/60 Hz)
Allowable voltage fluctuation [V]
Single phase 85 to 132 VAC
Single phase 170 to 253 VAC
Rated current [A]
0.4
0.2
Applicable Fieldbus protocol
SSCNET
#
(High-speed optical communication)
Communication function
USB communication
Operating temperature range [
°
C]
0 to 55 (No freezing)
Operating humidity range [%RH]
90 or less (No condensation)
Storage temperature range [
°
C]
–20 to 65 (No freezing)
Storage humidity range [%RH]
90 or less (No condensation)
Insulation resistance [M
Ω
]
Between the housing and SG: 10 (500 VDC)
Weight [g]
800
1000
Model
LECSC1-S5
LECSC1-S7
LECSC2-S5
LECSC2-S7
LECSC2-S8
Compatible motor capacity [W]
100
200
100
200
400
Compatible encoder
Absolute 18-bit encoder
(Resolution: 262144 p/rev)
Main
power
supply
Power voltage [V]
Single phase 100 to 120 VAC
(50/60 Hz)
Three phase 200 to 230 VAC (50/60 Hz)
Single phase 200 to 230 VAC (50/60 Hz)
Allowable voltage fluctuation [V]
Single phase 85 to 132 VAC
Three phase 170 to 253 VAC
Single phase 170 to 253 VAC
Rated current [A]
3.0
5.0
0.9
1.5
2.6
Control
power
supply
Control power supply voltage [V]
Single phase 100 to 120 VAC
(50/60 Hz)
Single phase 200 to 230 VAC
(50/60 Hz)
Allowable voltage fluctuation [V]
Single phase 85 to 132 VAC
Single phase 170 to 253 VAC
Rated current [A]
0.4
0.2
Communication
specifications
Applicable Fieldbus protocol (Version)
CC-Link communication (Ver. 1.10)
Connection cable
CC-Link Ver. 1.10 compliant cable (Shielded 3-core twisted pair cable)
*
1
Remote station number
1 to 64
Cable
length
Communication speed [bps]
16 k
625 k
2.5 M
5 M
10 M
Maximum overall cable length [m]
1200
900
400
160
100
Cable length between stations [m]
0.2 or more
I/O occupation area
(Inputs/Outputs)
1 station occupied (Remote I/O 32 points/32 points)/(Remote register 4 words/4 words)
2 stations occupied (Remote I/O 64 points/64 points)/(Remote register 8 words/8 words)
Number of connectable drivers
Up to 42 (when 1 station is occupied by 1 driver), Up to 32 (when 2 stations are occupied by
1 driver), when there are only remote device stations.
Command
method
Remote register input
Available with CC-Link communication (2 stations occupied)
Point table No. input
Available with CC-Link communication, RS422 communication
CC-Link communication (1 station occupied): 31 points
CC-Link communication (2 stations occupied): 255 points
RS422 communication: 255 points
Indexer positioning input
Available with CC-Link communication
CC-Link communication (1 station occupied): 31 points
CC-Link communication (2 stations occupied): 255 points
Communication function
USB communication, RS422 communication
*
2
Operating temperature range [
°
C]
0 to 55 (No freezing)
Operating humidity range [%RH]
90 or less (No condensation)
Storage temperature range [
°
C]
–20 to 65 (No freezing)
Storage humidity range [%RH]
90 or less (No condensation)
Insulation resistance [M
Ω
]
Between the housing and SG: 10 (500 VDC)
Weight [g]
800
1000
Series
LECS
LECS-P06-CS3e.indd 6
14.1.31 8:06:58 PM