background image

 

 

ASSEMBLE FRONT PANEL 

BOTTOM PLATE 

1834mm 

1834mm 

TOP PLATE 

15mm 

15mm 

15mm 

15mm 

SELECT: 

 

1 x 1.890 Wall Sheet 

1 x 1.520 Top Plate (Red) 

1 x 1.520 Bottom Plate (Green) 

1 x 1.890 Door Jamb Flashing 

1 x 1.890 Corner Door Jamb Flashing 

16 x 30mm Galv Clouts 

13 x Rivets 

STEP 1: 

 

 

Lay out 1 x Top Plate and 1 x Bottom Plate on a flat 
surface as shown  

STEP 2: 

 

 

Using 2 x 30mm clouts, nail the Door Jamb Flashing flush with 
the top of the Top Plate at the correct  measurement as shown 
in plan view. Pre drill holes using a 3.5mm drill bit 

 

 

Check the distance between the top and bottom plates then use 
a further 2 x 30mm clouts to nail the Door Jamb Flashings to 
the bottom Plate. Pre drill holes. 

STEP 4: 

 

 

Place the door on the panel (In open position, approx 5mm 
below top plate). Using two rivets, rivet the top and bottom 
hinges to the Door Jamb Flashing.  

 

 

Ensure the door closes properly, then fit remaining rivets. 

STEP 3: 

 

 

Place 1 x Wall Sheet on timber plates and rivet the sheets 
together as shown. 

 

 

Ensure that the top of the sheet is flush with the top of the 
Top Plate and that the sides of the wall sheet overhang the 
Top Plate by 

15mm

 as shown. Nail wall sheets to Top Plate 

(two clouts per pan) 

 

 

Nail the wall sheets to the Bottom Plate making sure that the 
Plates are the correct distance apart and that the sides of the 
wall sheets overhang the Bottom Plate by 

15mm

 

 

Drill & rivet Door Jamb Flashings to wall sheets using four 
rivets equally spaced on each side. 

NOTE: 

The

 

Doorway is standard at the left-hand end but can 

be put on the right-hand end.

 

TOP

 

PLATE

 

DOOR

 

JAMB

 

NAIL

 

NOTE: 

Door can be hinged on either side.

 

IMPORTANT—IF YOU CHOOSE TO RAISE YOUR TIMBER 

BASE PLATE –READ THE FOLLOWING; 

 

For sheds with Raised Base Plate option only (see page 5), deduct 

30mm from measurement shown between Top and Bottom Plates on 
all wall panels, so cladding protrudes 20mm below bottom plate

960mm

 

TOP PLATE 

DOOR OPENING 

Plan View

 

15mm 

530mm

 

x3

 

x3

 

x3

 

Содержание SS1515

Страница 1: ...ASSEMBLY INSTRUCTIONS SS1515 BASE SIZE 1 520m x 1 520m...

Страница 2: ......

Страница 3: ...r cladding used in Smart Store Sheds Wash all surfaces annually using a hose and soft nylon brush Within 2 km of coast wash every 3 months as above After a storm wash the cladding and the gutters as s...

Страница 4: ...3 Door Brace 1 255 m 2 Door 3 4 Sheet 1 850 m 2 Barge 1 720 m 2 TIMBER Padbolt Support 0 140 m 1 Bottom Plates H4 Green Front Back 1 520 m 2 Spouting 1 550 m 1 Bottom Plates H4 Green Sides 1 520 m 2...

Страница 5: ...ont Bottom Plate Side Back Wall Sheets Front Wall Sheet Door Jambs Door Sheets Door Side Flashings Padbolt Support Flashing Hinge Door Brace Door Top Bottom Channel QUICK OVERVIEW 1 LAY FOUNDATION 2 A...

Страница 6: ...coming through from underneath During construction you may raise the bottom timber plate to allow the wall cladding to protrude 20mm below the bottom plate This will stop water flowing between the bot...

Страница 7: ...fig 1 Rivet sheets together STEP 2 Position door side flash ings and assemble door as shown Drill and rivet as per dia gram ensuring rivets penetrate into door sheet STEP 4 Rivet door brace flashings...

Страница 8: ...ing each side of wall sheets overhangs the end of Bottom Plate by 15mm Check that the distance between the Top and Bottom Plates is correct As per diagram in step 1 Check that the Bottom Plate is stra...

Страница 9: ...e wall sheets overhang the Top Plate by 15mm as shown Check that the Top Plate is straight then nail wall sheets to the Top Plate using two clouts per pan STEP 4 Nail the wall sheets to the Bottom Pla...

Страница 10: ...properly then fit remaining rivets STEP 3 Place 1 x Wall Sheet on timber plates and rivet the sheets together as shown Ensure that the top of the sheet is flush with the top of the Top Plate and that...

Страница 11: ...s while they are screwed together Before fixing ensure that the Side Panel overlaps the Back Panel Using 4 x 40mm screws 2 per join screw the Top and Bottom Plates together in the corners STEP 2 Repea...

Страница 12: ...s to the front back Top Plates using 1 x nail per pan fig 2 STEP 4 Place barge flashings on roof at end of shed ensuring the diagonal trimmed end is at the front Rivet the Barge Flashings to the roof...

Страница 13: ...to the Bottom Plate and the concrete slab A 10mm masonry drill bit is required OPTIONAL SENTRY FLOOR Position the Floor Joists equally between the side Base Plates and skew nail each end with two 75mm...