Figure B – Mounting Information
The
C4 compact ME series
comes with mounting brackets as standard. The mounting brackets
are located at the ends of the safety light curtain as shown above. The mounting bracket may
be fixed at 90 degrees, with a +/-5˚ adjustment.
Use 4mm bolts for mounting and ensure they are fixed so as to prevent any movement or
loosening of the safety light curtain.
The
C4 compact ME series
does not use cable connectors. Both the transmitter (Tx) and
receiver (Rx) units come complete with 5m cables attached.
Transmitter = 3 core cable.
Receiver = 7 core cable.