![SMARTSCAN C4 compact ME Series Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/smartscan/c4-compact-me-series/c4-compact-me-series_installation-manual_1298237047.webp)
Safety Light Curtain – C4 compact ME Series
Installation Guide
File Number: CD1011
page 47 Date: 12 April, 2017
PFHd (Per Hour)
1.66958E-09
T1 (Life Span in Years)
20 Years
MTTFd (Years)
100 Years or more
DC (Diagnostic Coverage) % 99%
Warranty One
Year
OUTPUTS
Safety Outputs
OSSD1 & OSSD2
2 x electronic switches (PNP), each rated at 24V DC, 500mA
Synchronization I/O
INPUTS
Safety Monitoring (EDM)
Reset (Manual/Automatic)
Synchronization I/O