under reach to the danger point. It must not be possible to stand between the safety light
curtain and the danger point.
The protection afforded by the safety light curtain should correspond to the machine Risk
Assessment under ISO 12100 for the machine being guarded.
4. Ensure the light curtain transmitter (TX) and receiver (RX) units are mounted accurately
in-line with each other and are both perpendicular and parallel to each other within the
parameters shown for each axis.
5. If utilising mirrors to deflect the light curtain ensure the mirror length is 50mm longer at either
end of the light curtain detection zone width and mounted centrally to the zone. To ensure
reliable operation the light curtain deflection angle (A) from the mirror must not be less than
40 degrees or greater than 100 degrees. (See Appendix 3)