EQUIPMENT/SETTINGS VERIFICATION 

Verify that the Job Specification parameter table on the drawings 
“Sheet 1: Getting Started” matches the actual equipment.  
Below  is  a  sample  table  showing  the  important  values  that  will 
affect operation.

  

 

 

 

 

 

 

 

Sample: Sheet 1: - Getting Started 

Motor 

Volts 

Motor 

Amps 

Motor 

RPM 

Motor 

Poles 

Motor 

HP 

Brake Volts 

Pick/Hold 

Encoder 

PPR 

Main Line 

Volts 

Motor 

Frequency 

Содержание Magnetek L1000A

Страница 1: ...DRIVE STARTUP MANUAL Magnetek L1000A Drive Permanent Magnet Installation www smartrise us 2601 Fair Oaks Blvd Sacramento CA 95864 916 457 5129...

Страница 2: ...le on the drawings Sheet 1 Getting Started matches the actual equipment Below is a sample table showing the important values that will affect operation Sample Sheet 1 Getting Started Motor Volts Motor...

Страница 3: ...side of the incoming water main To a grounding rod that has been driven into the pit flooring The controller has a common ground bus terminal connection All grounds need to land at this common point i...

Страница 4: ...ls K1 K2 and the secondary brake wiring if equipped to terminals J1 J2 located on the terminal block next to the M contactor Jump EB to the terminal listed in the Construction box located on Sheet 01...

Страница 5: ...s if required Pre Transfer Emergency Power Governor IMPORTANT REMOVE FACTORY WIRES ON INPUTS 521 522 o Install the Run Bug Up Down Switch to IO s 521 522 Install the Run Bug Up Down Enable switch to M...

Страница 6: ...ck off box when complete Toggle the Inspection Normal switch to the INSP position Set BYPASS TERM LIMITS to YES o On the Smartrise Machine Room controller board press the Left Arrow ESC button several...

Страница 7: ...press the enter key o Use the Up Down Arrow keys to change the word NO to YES o Use the RIGHT Arrow key and move the asterix under the word SAVE and press enter o Hit the LEFT Arrow ESC button several...

Страница 8: ...ntil the Auto Tuning display appears 4 Press ENTER key to begin setting parameters a Press ENTER key to select the value for T2 01 Set to 1 5 Save the setting by pressing ENTER 6 The display automatic...

Страница 9: ...motor nameplate press UP arrow key to confirm and get to Tuning Ready message 3 Press and hold down the M Contactor during the duration of the Auto Tune 4 Press RUN to activate Auto Tuning Auto Tuning...

Страница 10: ...ection Make sure the car is moving in the same direction as the control switch on the Run Bug o Go to Troubleshooting Wrong Direction for corrective actions At Speed Make sure that the car is moving a...

Страница 11: ...tarted If it has the proper voltage check the following a During a run command check for DC voltage between points K1 K2 and J1 J2 if 2nd brake installed Verify the voltages are also at the Brake Coil...

Страница 12: ...12 APPENDIX Terminal Locations Terminal Card location on PG card Encoder wiring terminals GND terminals Main Line terminals L1 L2 L3 Motor terminals T1 T2 T3 Brake terminal block...